As the clothes gently toss about inside the drum, a temperature control thermostatic disk regulates the heat. It is set for 160f for cotton and it mounts on the blower housing. As air is drawn into the drum and out the backside of the dryer the heat is regulated by this control. It sends 120 volts to the gas assembly. Right next to it is a fuse. The duct fuse is set to blow at 250f. Should that control fail to open and allow for heat to build to abnormally high temps. Note: the fuse will kill the heat source only on most dryer, the dryer will however continue to run. Lint and vent blockage can restrict the airflow and make the heat inside build to dangerous levels.The control thermostat powers up the heat for a minute then shuts down for a few minutes, then repeats this all throughout the drying process, the gas does not stay on! That would burn the clothes. If both of those items check ok and the dryer vent and lint has been cleaned, I next take a look at the gas assembly. I check the flame sensor first. If the flame sensor is open the ignitor will not glow. If that turns out to be good I next check the ignitor itself for continuity. If it turns out to be good I replace the coils. Those coils cannot be checked because they do not act up until energized. Sometimes the coils will work, get hot and fail, cool down and work again. I have some repair photos:
HERE
If you need further help, reach me via phone at
https://www.6ya.com/expert/dan_73bbd84fe1d95b61
×