Posted on Jan 31, 2010

Onan Generator stopped working in motorhome because the gas got too low. I blew out the front fuel filter,changed oil and filter, air filter, one spark plug and now it won't start. Is there a fuel shut off valve that automatically stays shut when the gas from the motorhome fuel tank gets below 1/8 tank? No fuel is getting to the front fuel filter of the Onan Genset 400 BHE now and it will not start. Could it be a shut off valve or the fuel filter?

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Problem Solver:

An expert who has answered 5 questions.

  • Contributor 9 Answers
  • Posted on Feb 01, 2010
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Problem Solver:

An expert who has answered 5 questions.

Joined: May 12, 2008
Answers
9
Questions
0
Helped
4410
Points
13

Yes it wil not let you run your motorhome out of fuel they set it up that way so you dont strand yourself you may have a air bubble in the fuel line to the generator try blowing air generator fule line back into the tank

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My 2015 motorhome Onan rv qg 5500 gas generator turns over but won’t start , is there a safety kill switch that is the problem?

is it getting spark is it getting fuel kill switch doesnt let turn over --on off switch lets it turn over ----check for spark ---if spark check fuel --fuel filter - air filter etc --last time tune done --carb may need cleaning --rebuild or replacement etc
0helpful
1answer

Onan generator cranks then wines no start i have a onan generator in my motorhome it stop running now when i try to start in it turns over but does not run what should i9 cheack

check oil level in the sump
if the oil level is correct check for a problem oil level sensor circuit
it is there to stop the engine when the oil level reaches critical level
0helpful
1answer

Kubota troubleshooting

Try bleeding the generator as some air could have entered in the system.
1helpful
2answers

My generator will turn over but wont start

Our motorhome Onan 5000 Marquis generator will turn over and try to start but fails everytime we test. We have primed, gas and oil are fine and we have new spark plugs. We also changed the gas filter on the generator. Any suggestion? Thanks, Loretta
0helpful
1answer

Have a 2.0kva-fr/26119 onan genorator which runs for 5 minutes and stops can you be of any help

If it stops after 5 minutes whether under load or not, and assuming the air filter, plugs, and fuel filter are new and or clean. The fuel pump is suspect. If it is in a motorhome try conencting it to an external fuel source that is at the same height as the generator. Then higher than the generator. If the problem persisits replace the fuel pump. Or just check fuel pump pressure with a gauge. BE CAREFUL do not use an automotive fuel pump Onan have special low pressure pumps, so use OEM part
1helpful
1answer

Generator trouble starting and running rough

ok simple things first, new spark plug, fresh gas, a decent dose of fuel cleaner a bottle doses 12 gallons so say if 3 gallons gas use 1/4 bottle (yes double dose wont hurt) , air filter, try running this first and see if it picks up over time, the methanol gas really crude's up small engines and the cleaner will hopefully clear it up, use fuel stabilizer with ethanol protection and dont let tank sit empty always full to keep moisture to lowest level. if this doesnt work then likely carb is fouled and needs rebuild
Jun 03, 2012 • Hammering
0helpful
1answer

Starts easily, run for 5 to 20 minutes and then

If the fuel filter (strainer) is OK, carb gives enough fuel for the load you apply, air filter is dry and clean, your problem may be the low oil level protection.
Check if generator is at level position.
After the oil is distributed in all the engine its level may go less than the measuring sensor level. Try to put some more (not much) oil. 
If this will not help your measuring sensor may be bad and switch off when the oil gets hot.
0helpful
2answers
Not finding what you are looking for?

1,528 views

Ask a Question

Usually answered in minutes!

Top Watts Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Watts Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...