Check the toner bottle to ensure that it is feeding toner into the sub hopper unit under the bottle. Sometimes users will insert the bottle incorrectly and not lock it properly in place...the lever on the front of the toner hopper for that bottle is moved down to the left to remove and insert the bottle.
Dec 28, 2010
Does the control panel say replace PC drum? You need to have the Drum/Developer and the Developing unit replaced. Make sure that the counters are cleared before removing the old unit and make sure F8 is run after the new image unit is installed
c-2557= ATDC Sensor abnormality
to reset go to service mode,
to enter service mode perform these steps,
1-press utility/counter button from the panel,
2-press check details, and press "STOP" 0,0, STOP 0,1
3-now you are in service mode,
4-click on tech rep mode,or Adjustment
5-now click on "Printer"
6-here increase the value, suppose you have 150, make it 170, press the clear button to clear it and enter new value which should be more than the previous one.
press enter and exit from the service mode.
×