Can u solve me Eoo1 Eoo3 ?
E001 0000 Abnormally high temperature (detected by main thermistor)
The main thermistor detected an
abnormally high temperature (240 deg
C) during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
0001 Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an
abnormally high temperature (295 deg
C) during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E003 0000 Abnormally low temperature (detected by main thermistor)
After the temperature detected by the
main thermistor has reached the
specified value, it does not reach the
specified value during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
0001 Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the
sub thermistor has reached the
specified value, it does not reach the
specified value during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
Testimonial: "tank you."
Blank output in canon ir 2016j photocopier
390 views
Usually answered in minutes!
E001 E003 can u give me solution?
×