If the burner comes on and then after a while the burner turns off for a short time, minute or less then starts again, you might have a problem with your fan motor or a very dirty air filter. I could be going off on high limit and then resetting and working that squence of operation. Also if your unit has been worked on recently, a larger then needed nozzel could have been installed and the unit fan can not cool the heat exchanger quick enough.
102 views
Usually answered in minutes!
Sorry took so long I was at work. The whole thing shuts off momentterelly. I notice now i smell a lot of kero. thanks again
Hi, Does the fan and burner click off and on or just the burner? Or just the blower? That info will help narrow down the problem... Thanks!! Heatman101
×