Tally 6306 Matrix Printer Logo
Posted on Dec 13, 2009

The 6306 L showing HAMMER VOLTAGE 1 ERROR WHAT SHOULD I DO

4 Answers

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 1 Answer
  • Posted on Jul 05, 2010
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Jul 05, 2010
Answers
1
Questions
0
Helped
2550
Points
3

ERROR IS BECAUSE OF DRIVER IC FAULTY IN LOGIC CARD
PLZ CHANGE THE HAMMER DRIVER IC IN LOGIC CARD

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 1 Answer
  • Posted on Aug 30, 2010
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Aug 30, 2010
Answers
1
Questions
0
Helped
2550
Points
2

Hammer voltage 1 in lipi 6306 line printer

Ad

Anonymous

Level 1:

An expert who has achieved level 1.

Habit-Forming:

Visited the website for 3 consecutive days.

New Friend:

An expert that has 1 follower.

Welcome Back:

Visited the website for 2 consecutive days.

  • Contributor 1 Answer
  • Posted on May 13, 2010
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Habit-Forming:

Visited the website for 3 consecutive days.

New Friend:

An expert that has 1 follower.

Welcome Back:

Visited the website for 2 consecutive days.

Joined: May 13, 2010
Answers
1
Questions
0
Helped
2550
Points
4

LINE PRINTER 6306 showing HAMMER VOLTAGE 1 ERROR PI.TELL ME WHAT CAN I DO.
MAIL ID [email protected]

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Oct 05, 2012
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Aug 19, 2011
Answers
1
Questions
0
Helped
2550
Points
1

Power on the printer by connecting one hammer cable i.e. J101/J102 at a time . If it again shows hammer voltage 1 than driver ic of that particular section ( J101 or J102 ) is faulty. It will be easier to solve the problem.

2 Related Answers

Anonymous

  • 2 Answers
  • Posted on May 04, 2011

SOURCE: talley 6306 showing fault: hammer

Hammer Voltage 2:

A high resistance coil fault has likely occurred in one or more of the hammer coils. Note: this fault message will have been preceded by printing slow-down attempts associated with On-The-Fly thermal monitoring of hammer bank temperature.

Solution:

Check the hammer bank for defective coils.
Replace the Controller Board

Ad

Anonymous

  • 6 Answers
  • Posted on Apr 15, 2010

SOURCE: fault hammer voltage 1 problem facing in lipi 6306

it is good.
We are always here to serve your needs and provide quality service. Ourproducts range include replacement computer batteries for most majorlaptop brands, including Dell, Apple, Compaq/HP, IBM/Lenovo, Fujitsu,Gateway, Sony and Toshiba. <a href=http://www.bestlaptopbattery.co.uk>laptop batteries</a>

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

What does HAMMER VOLTAGE 1 ERROR indicate?

There is a short on the hammer drive circuit. It can be caused by the
HammerBank
TALLYGEN 093524 HAMMERBANK T6306 Refurbished
The Main Logic, the link is for the standard one, but if you have a Graphics selection then you will need a different one.
TALLYGEN 086153 CONTROLLER KIT STANDARD T6306 Refurbished

And in rare cases the hammer bank cables, but you will normally see a break in the cable if that is the case.
0helpful
1answer

Hammer voltage 1

try to find out datasheet of q8 and q20 and notice the input voltage to mosfet and out put voltage.generally check the electrolytic capasitor, serrounding diod od q8 q20,and also q9 q20 mosfet.
0helpful
2answers

Faulty Hammer voltage-2 earr

There is most likely a fault with one of the hammer coils, this would need investigating, other possible causes;Faulty / damaged ribbon cableFaulty main boardUpdate firmware, the error should change to a more meaningful error with later firmware
0helpful
1answer

Tally 6306 Matrix Printer hamer voltage 1 Error

Hammer voltage 1 is generally the logic board. One of the driver fets have gone bad. If you have schematics for the board you can fix otherwise a new board is required. Moving the temp cal is a bad idea. can cause a fire real easy.
0helpful
1answer

Talley 6306 showing fault: hammer voltage 2

Hammer Voltage 2:

A high resistance coil fault has likely occurred in one or more of the hammer coils. Note: this fault message will have been preceded by printing slow-down attempts associated with On-The-Fly thermal monitoring of hammer bank temperature.

Solution:

Check the hammer bank for defective coils.
Replace the Controller Board
1helpful
2answers

I GOT PROBLEM IN TALLY 6303.ERROR CODE IS HAMMER VOLTAGE 1 FAULT, CAN U HELP ME WHUCH IC OR CHIP FAULTY

It could be the problem with your Hammer bank/ Hammer bank cable or MLC, Some cases dusty hammer bank .
26helpful
3answers

Problem for lipi 6312 tally genicom line printer my printer shows an error (hammer voltage 1)

problem for lipi 6312 tally genicom line printer my printer shows an error (hammer voltage 1)
1helpful
1answer

Fault hammer voltage 1 problem facing in lipi 6306 line printer pls give the suggestion to solve this gopi

it is good.
We are always here to serve your needs and provide quality service. Ourproducts range include replacement computer batteries for most majorlaptop brands, including Dell, Apple, Compaq/HP, IBM/Lenovo, Fujitsu,Gateway, Sony and Toshiba. <a href=http://www.bestlaptopbattery.co.uk>laptop batteries</a>
1helpful
6answers

How I can solve hummer voltage 1

You must check the adjustment of your AVR and the Machine Voltage Switch.
1helpful
2answers

HUMMER VOLTAGE ERROR

There are two different Hammer Voltage errors on the 6306; Hammer Voltage 1 and Hammer Voltage 2.

Hammer Voltage 1:

One of the hammer drive circuits was turned on when it shouldn’t have been, so all printing has been disabled. The usual cause is a failed drive transistor.

Solution: Replace the Controller Board.

Hammer Voltage 2:

A high resistance coil fault has likely occurred in one or more of the hammer coils. Note: this fault message will have been preceded by printing slow-down attempts associated with On-The-Fly thermal monitoring of hammer bank temperature.

Solution:

Check the hammer bank for defective coils.
Replace the Controller Board
Not finding what you are looking for?

2,560 views

Ask a Question

Usually answered in minutes!

Top Tally Office Equipment & Supplies Experts

NOEL
NOEL

Level 3 Expert

8606 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Tally Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...