I have a Jet AFS-1000B ceiling mounted Air Cleaner that has not logged many hours. In fact, the original air filters are still clean. The problem is that it shuts down after running a short time. When the filters are installed the time is much shorter. It seems that the motor might be overheating. It can be restarted after a short time but the time running is seldom longer than 30-45 seconds. The unit is over 10 years old so the warranty expired long ago.
Bill
I had similar issues and by replacing the 2200 micro (Mu) Farad, 10 Volt capacitor on the PCB, all of my issues ceased.
Below is a link with information supplied by "fixya" that explains the procedure/details.
Hopefully this will solve your current issues.
Good luck,
Mike
http://potlash.org/feast/2010/11/20/repairing-a-jet-afs-1000b/
PS Linda Haus of "Rockler" Technical Support was kind enough to supply me with this link.
227 views