10V 450uf cap in high Voltage section... replace both not just the one. Caps tend to dry out and cause short on nearby regulator if left go too long. Do not continue to run the TV without replacing the caps first that are leaky. They are the Larger of all Electrolytics on high voltage board and manuf is Sanyo Brown with silver stripe. Typically the bottom of the two caps goes first.