A
Alan kinnard Posted on Oct 05, 2019
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Wiring diagram for woods timer model 59104m - Woods Hardware & Accessories

1 Answer

Gene Haynes

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Woods Master 5,391 Answers
  • Posted on Oct 26, 2019
Gene Haynes
Woods Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 07, 2012
Answers
5391
Questions
0
Helped
2606177
Points
14124

Product images and manuals with wiring diagrams for all models of this timer appear on following link
http://waterheatertimer.org/Woods-timers-and-manuals.html#59104

2 Related Answers

Anonymous

  • 1 Answer
  • Posted on Mar 20, 2011

SOURCE: WIRING DIAGRAM FOR A FRONT LOADER WASHING MACHINE

Diagram of internal wiring of ariston AV41washing machine

Ad

Gene Haynes

  • 5391 Answers
  • Posted on Nov 27, 2012

SOURCE: lake wood model 7096 wiring diagram

Is this electric water heater?
Does it have 1 or 2 elements?
http://waterheatertimer.org/How-to-wire-water-heater-thermostats.html
http://waterheatertimer.org/images/WH-w-combined2-1000.jpg
http://waterheatertimer.org/How-to-troubleshoot-electric-problems-with-water-heater.html

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I need to connect a photocell to a timer and a contactor. Please can anyone help me with wiring diagrams or solutions

Have illustration of photocell on 240Volt T104 timer circuit:
http://waterheatertimer.org/images/T-104-control-240V-Load4-2-photeye-240V.jpg

Some timers have built-in photoeye:
http://waterheatertimer.org/Woods-timers-and-manuals.html#outdoor

Can make any wiring illustration if timer and voltage and load are known: with specific detail about the project.
http://waterheatertimer.org/How-to-install-and-troubleshoot-photo-eye.html

Gene
h

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

TP8B16 digital timer instructions

1) Copy following links to identify timer and download possible manual, and see general wiring diagram:
http://waterheatertimer.org/Woods-timers-and-manuals.html#TE22
http://waterheatertimer.org/How-to-install-3-phase-timer.html#T80

2) Feb 2013. Add comment and describe timer voltage and include what you are controlling for additional help as needed.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

How do I wire a Woods 59402 timer 240v input running two 120v outlets

Woods 59402 timer wires identical to Intermatic GM40, with same ratings and dip-switch settings.
http://waterheatertimer.org/How-to-wire-GM40-timer.html

Here is specific wiring diagram per your request, showing 240Volt input controlling two 120Volt outlets.
http://waterheatertimer.org/images/GM40-wiring-240v-120-volt-5.jpg
http://waterheatertimer.org/See-inside-main-breaker-box.html

Keep in mind that with 240Volt, both hot wires coming from breaker box carry 120Volt each, with 240Volt potential across both hot leads.
Each 120Volt Hot from breaker box, also carries 120Volt potential to Neutral or ground wire.
So the 240Volt wires from breaker box can supply the Hot for a 240Volt circuit, but the circuit must also have a neutral wire to complete 120Volt circuit.

Be mindful that timer is not 2-channel, so both outlets are controlled by same timing schedule.
If you want two different schedules for the outlets, then buy a 2-channel timer like Intermatic ET1125. Wiring for ET series remains similar to illustration link above.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Remeha plus timer

Are you looking for a 230Volt 50Hz timer?
Or wiring diagram.
Or manual?
Copy following link to help identify timer and download possible programming manual:

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

I need to know where the wire from the omron off delay timer connects to the motor starter contacts.

Which Omron timer?
The model and wiring diagram appear on side of timer.
Add a comment with more details and I can track down the information.

http://waterheatertimer.org/How-to-wire-pin-timers.html
http://waterheatertimer.org/Woods-timers-and-manuals.html#Omron

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer

Wiring diagram for Omron off delay timer

Which Omron timer?
The model and wiring diagram appear on side of timer.
Add a comment with more details and I can track down the information.

http://waterheatertimer.org/How-to-wire-pin-timers.html
http://waterheatertimer.org/Woods-timers-and-manuals.html#Omron

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

0helpful
1answer
0helpful
1answer

Lost wiring instructions for my woods water heater timer. What wires attach to bus bar

Timer model is usually located inside the door panel:

1) Open following link to access manual with wiring diagrams.
http://waterheatertimer.org/Woods-timers-and-manuals.html#Boxtype

2) Example manual shows different wiring diagrams:
http://waterheatertimer.org/pdf/Woods-59396-59399-manual.pdf
If you have timer with 8 terminals, and ordinary 240V water heater, then use diagram on bottom right.

3) Woods timers are wired identically to GE 15207, except your model might not have dip switches.
http://waterheatertimer.org/How-to-wire-GE-15207-timer.html

4) Busbar usually refers to a long metal bar where many wires connect to same pole. For example neutral busbar inside breaker box has 20 or 30 wires connected to it, and all are connected to Neutral wire from power pole.
http://waterheatertimer.org/See-inside-main-breaker-box.html
http://waterheatertimer.org/B220C.html

5) Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.
3helpful
1answer

The old timer that was there quit working tryed to put a new woods one in but cant get it to work help

The following wiring diagram works for Woods, GE, Hagar, Leviton, Sylight, Utilitec, some Intermatic in-wall timers.
It does not apply to Aube timers or Intermatic battery-operated timers.

geno_3245_1.jpg

If the wires are not connected correctly, the timer will not operate as expected.
Click the manual override and see what happens.
If the lights do not turn ON with the manual override, then the wiring is suspect.
If the lights blink, then you have put the red and white wires together.
If the lights turn ON, but timer clock is not working, it is possible you have the black and red wires reversed.
If the white wire is not connected correctly, the clock mechanism will not operate.

Review the wiring.
Black-timer wire goes to black-hot-wire from breaker
Red-timer wire goes to black-wire going to Load (lights)
White-timer wire connects to the Neutral wires that are usually twisted together and covered with a wire nut.
IF your box does not contain those white wires, then you can work-around by connecting white wire to bare ground wire.
0helpful
1answer

How do I wire the timer in a 3-way switch?

Woods 59013 59017 59018 59720 59028 etc wall timers are not made for 3-way application. They replace a simple on-off switch.

Atube T1032-3W programmable timer shows it can replace 3-way switch.
See manual
Smarthome

Intermatic ST01C & EJ500 programmable times can replace 3-way switch. Look at diagrams carefully. Circuit is limited to 100' distance because of battery.
See wiring diagram
Aplus

Lutron makes several 3-way countdown timers that turn on light for certain length of time and then turn off light

Tip for 3-way switch replacement: Mark wire that connects to dark-colored screw. This is called the 'common' wire.
Depending on location of switch, the 'common' wire either goes to Load (lights) or it comes from breaker box as Hot wire.
Not finding what you are looking for?

697 views

Ask a Question

Usually answered in minutes!

Top Woods Hardware & Accessories Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

NOEL
NOEL

Level 3 Expert

8606 Answers

Are you a Woods Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...