I have a Onan Marquis Indiana 5000 generator. When I connected 240 mains to the RV I did not disconnect the plug of the genset. Although genset was not runnig at the time. There is now no 240 from the genset. Can anyone help with this problem as I can not find any information on the Onan website regarding this?
You MAY have blown the rotating diodes on the rotor.
This would require servicing.
CHECK THE OUTPUT TERMINALS OF THE GENERATOR WITH YOU OHM METER ON X1 SCALE AND THE ENGINE NOT RUNNING. IF THERE IS A GOOD CIRCUIT, LESS THAN 5 OHMS, THEN CHECK THE ROTATING DOIDES ON THE ROTOR IF IT IS THIS DESIGN. CHECK THE REGULATOR IF IT IS THIS DESIGN.
1,099 views
Usually answered in minutes!
Thanks fredy2. Makes sense now. I'll check this out and let you know how I get on. Thanks
×