I have a Honda eu3000is generator that didn’t run, well Barkley ran on full choke. I unplugged all the wires to the inverter and started the generator and it fired right up. When plugged the inverter back I while it was running it shut down again. Does this mean the invertor is bad? Or could it be the stator?

1 Answer

John

Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

  • Contributor 22 Answers
  • Posted on Feb 14, 2019
John
Contributor
Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

Joined: Feb 19, 2013
Answers
22
Questions
0
Helped
30125
Points
37

I would suspect that the inverter is fine and would look towards carburetion. The inverter, in addition to supplying the correct voltage and current, monitors the current being drawn by your connected load. It controls that stepper motor on the top of the carburetor and increases the throttle to increase the engine power to support the load. (Mechanical power in = electrical power out.)
Start the generator and then add a small load to the outlet, 100 watt light bulb or something. I use a space heater that I can turn on just the fan. See if it still stays running. Then increase the load (with my heater I go from fan only to the first level heat 1000w) and watch the top of the carburetor to see if the inverter increases the throttle to compensate for the increased load. By the sounds of what you are describing, it will go to full throttle and the engine will die because of a restriction on the available fuel. If that is the case, take the carb off and clean it. Or if you are not the carburetor rebuilding type, buy a new one.. they are only about $80. Not a bad fix for a $2000 generator :)

5 Related Answers

Anonymous

  • 149 Answers
  • Posted on Feb 01, 2009

SOURCE: How to connect a Honda EU3000is Generator to run the home furnanc

In shor NO.....

1st item to buy if you must conect to your house is a change over switch.it HAS TO ISOLATE THE MAIN LINE TO THE HOUSE< OR YOU WILL KILL SOME ONE....the other thing you have to know is the house just a single phase or a multi.....to save you life and the lines man working on the line when you run your genset, get a contractor to do it....

Ad

Anonymous

  • 1 Answer
  • Posted on Apr 29, 2009

SOURCE: honda em2500 starts, runs 1 minute, quits and will not restart

If the oil level is low it will do this, but I also know this to happen when the oil is very cold (thick) an won't fow back own o the crankcase where the oil sensor is. The slow return results in a low oil level. My solution is to start it, when it dies wait a couple of minutes and retry... after a few starts, the oil will warm up, thus flowing back down faster and it then will run. Another option is to use a thinner oil ie;5-30w.

Anonymous

  • 4088 Answers
  • Posted on Jul 14, 2009

SOURCE: Coleman 6250 generator runs rough

Fresh fuel? Does carburetor have adjustable jets? Turn the high speed jet (at bottom of float bowl) about 1/4 to1/2 CCW (looking at bottom of bowl). If no improvement, carburetor should be torn apart and cleaned. This also applies if there are no adjustable jets. Is there a fuel filter anywhere?

Anonymous

  • 1 Answer
  • Posted on Oct 09, 2009

SOURCE: Honda EU3000is Generator is running poorly.

Can anyone help me with the eco-trottle switch when I switch it on it seems to run the same idle whether I have it off or on, what could be causing it not to work, is it a bad switch or I am running 89 octane could that be the problem.

Thanks
Alex

witserv

William Robinson

  • 144 Answers
  • Posted on May 26, 2010

SOURCE: troy bilt 5550 generator no start please help

fuel, fire, mechanical. Miss one and she won;t run. Are you sure the gas was good? Not some old can laying around that may have turned or become water contaminated? If it was fresh gas, then take off the air cleaner and spray a little wd-40, or ether, or brake cleaner whatever is flammable into the carb throat. Just a 1 second shot is all it should need. Try and start with that. If it starts and then dies quickly, still a fuel problem. maybe a gasket is damaged, or the jet is clogged. When you said you checked for fire, you acutally took the plug out and had it grounded while spinning the motor and saw spark? If you saw a hot spark then you have eliminated fire. Mechanical not likely if it was running well a short time before. If a valve was damaged, it would still run but not too well. My gut feeling is it is related to fuel.

Testimonial: "thanks for the great help i did try fresh fuel and drained the carb bowl but still same prob its a head scratcher i really thank you for your input."

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Honda em 5000s runs but no power. took off alternator cover, AVR looks fine, can not find bushing?

Could be a bad breaker, A blown fuse on the generator (would be wired into the wiring of the alternator and taped up), bad connection on generator wiring or faulty generator wire. You may or may not need to replace the generator assembly.
1helpful
1answer

EU3000is inverter generator. Why won't it start?

Check the switch on /off is not faulty try taking the wire off the switch that goes to the motor mine had that problem (lot of dodgy switches fitted to them ,make sure the choke is closing on fully.check spark plug not fouled up with carbon.
1helpful
2answers

I just cleaned the carb and now it starts and runs fine, but starts burning oil after a couple of minutes. Did I get it wrong on assembly?

There is a series of spacers and gaskets that go on in a specific order. I can't remember offhand. If you get them on wrong it can mess up the alignment of the choke control which causes it to bind up and not move freely. That can make the engine run rich and smoke which makes it look like it is burning oil.
Check online for an exploded view of the gaskets and spacers along with the bracket for the choke control. Make sure they are aligned properly.
0helpful
1answer

Why does it start with the key when cold put not when its hot put i can pull start it with one pull?

You may have a cylinder head gasket problem either that or if this is a two stroke engine crank case pressure is critical, once hot there may be a pressure leak not enough to stop it from running once started but enough to stop you starting when warm, alternately a fuel evaporation problem not getting to pot before evaporating due to heat or blocked fuel jet when warm, if this unit has a choke is it disengaging a warm choked engine rarely starts and floods out smell of petrol will be high.
check that plug is not breaking down under pressure try another one check plug gap when warm it varies. hope this helps
0helpful
2answers

Honda eu3000is does not operate without choke

It sounds like your fuel mixture is too lean, closing choke is richening the mixture, by closing off air
0helpful
1answer

Honda EU 3000is only runs on half choke

Overhaul the carb. When you have to choke it to run, there is not enough fuel getting in
0helpful
1answer

Honda eu3000is generator surges

Inverter Generator Benefits
  • The EU3000 series generators are inverter generators. The generator features an alternator, which produced high-voltage, multi-phase AC power. This power is converted to DC power and then converted back to AC. This process is controlled by a microprocessor and is necessary to provide stable, consistent power capable of running equipment sensitive to power surges. This type of generator provides higher fuel efficiency and lower operational noise ratings in a lighter model than home and work generators produced by Honda.

EU3000i Handi Specifications
  • The Honda EU3000i Handi is a 3,000-watt inverter generator that features wheels, folding handle and a recessed convenience light. The engine is a Honda GX160, which features a 163-cc displacement. The AC output is 120 volts, with an average rating of 2,600 watts and a maximum production of 3,000 watts. There are three receptacles to include a 20A, 125-volt duplex and a 30A, 125-volt locking plug. The DC output is 12 volts and 100 watts. The EU3000i can hold 1.56 gallons of unleaded fuel, which will provide consumers with 3.6 hours of run time at 25 percent load for 7.7 hours.


performance chips of BMW.
0helpful
1answer

Wont run off 1/2 choke

I had a problem with a honda generator that would only run on full choke. I removed the carburetor and cleaned the main jet with a wire and carb spray. Problem solved. Fuel stabilizer should be used with todays gas mixtures that have ethanol in them. Hope this helps.
Not finding what you are looking for?

739 views

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...