Hello, i have aPower Star w7 3000 w 24v inverter/charger which has power working,tje alarm indicates over temperature trip. How must to make? I don't undertand over electronic system.

1 Answer

Brett Duxbury

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Master 4,352 Answers
  • Posted on Jun 04, 2018
Brett Duxbury
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Nov 12, 2012
Answers
4352
Questions
0
Helped
1120109
Points
13423

Look for components that are attached to heat sinks for a starting point . Heat sinks are big chunks of metal that absorb heat from components that generate heat . Power regulator components maybe a possible source of heat. Check their temperature while unit is running .

3 Related Answers

Anonymous

  • 1865 Answers
  • Posted on Nov 23, 2009

SOURCE: Our Inverter works but the battery charger seems

There is no way to guess what the problem is, we technicians use a multimeter to look at the electrical circuit values to determine the problem. The charging circuit could be bad, or the batteries could be shorted.

Ad

seijal agrawal

  • 20 Answers
  • Posted on Nov 25, 2014

SOURCE: Safe power evo HF siel,battery charger off due to

U can charge it by using the battery of any other device aid same power or else can change the battery

gopakumarg43

The Knight

  • 76851 Answers
  • Posted on Jan 14, 2015

SOURCE: Who can repair my Power star w7 6000/18000 48v inverter charger.

Any electronic equipment service technician can do it.
Gopakumar Gopalan Google

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Blue star Dx unit e2 alarm how to rectify

The Blue Star DX Unit E2 alarm is an error code that indicates a problem with the discharge temperature sensor. Here are some steps you can take to try and rectify the issue:
  1. Turn off the DX unit and disconnect the power supply to the unit.
  2. Check the wiring and connections of the discharge temperature sensor. Make sure the connections are tight and the wiring is not damaged or frayed.
  3. Clean the discharge temperature sensor. Remove any dirt, dust, or debris that may have accumulated on the sensor, as this can interfere with its readings.
  4. Check the sensor's resistance. Use a multimeter to check the resistance of the sensor. If the resistance is too high or too low, this may indicate a faulty sensor that needs to be replaced.
  5. Replace the sensor. If the sensor is faulty, replace it with a new one that is compatible with the Blue Star DX unit.
  6. Reset the unit. Once you have rectified the issue, reset the DX unit and see if the error code clears.
If you are unable to rectify the issue, or if the error code persists, it may be best to contact a qualified technician or Blue Star customer service for further assistance.
0helpful
1answer

At present I have a Xantrex Heart inverter/charger mod # 81 2511 12 {207} I am looking to replace it but i dont know the wattage

Xantrex Freedom Marine 25, Off Grid Inverter, 2500 Watts, 12 Volt, Portable
Manufacturer Part Number: 81-2511-12

Detailed Description:
AC Power Inverter with High Surge Capability, 3-Stage Charger.

  • MSW AC power inverter with high surge capability
  • Automatic 3-stage battery charger
  • Temperature compensation with equalization stage provides optimal charging of deep cycle batteries
  • Built-in transfer switch automatically transfers between inverter power and incoming AC power
  • Multiple battery bank charging from the built in 15 A echo~charge
  • Power sharing prevents source AC input circuit breaker from tripping
  • Customized settings can be programmed with the Freedom Basic Remote or Link panels
  • Aluminum chassis ideal for marine environment
  • Includes battery temperature sensor
  • 30 month warranty
Protection Features
  • Over voltage and under voltage protection
  • Over-temperature protection
  • Overload protection
  • Short circuit protection
Mar 21, 2022 • Boating
0helpful
1answer

Dc inverter show fault light

Inverter has alarm sound and red indicator light is on, which indicates abnormal phenomena caused by overvoltage/undervoltage/overload/overtemperature. The machine should be switched off immediately. Check the cause of the abnormality; remove it and then access it. Usually, the buzzing alarm is caused by the low voltage of your battery (bottle) or DC power supply (less than 10.4V alarm of inverters). It is necessary to start the vehicle to start charging your car engine or charge your battery (bottle) through the charger. https://www.dieselgeneratortech.com/generator-set
1helpful
1answer

COLEMAN INVERTER PMP1200 JUST BEEPS WHEN TURNED ON

It is most likely the low voltage alarm. Suggest connecting when the car is running with no load (110 volts not connected). If the alarm continues turn the unit off and on to reset.

Hope this helps?

Inverter Protection Features
• Short Circuit Protection. The inverter will automatically shut down until short is removed.
• Low Voltage Alarm. An alarm will sound when the voltage from the battery discharges to 10.5 +/- 0.5 volts DC. This is an indication that the battery needs to be recharged.
• Over Voltage Protection. The RED LED Indicator Light will illuminate and the inverter will automatically turn itself off when the input exceeds 16.5 +/- 1 volt DC.
• Under Voltage Protection. The RED LED Indicator Light will illuminate and the inverter will automatically turn itself off when the input is less than 10.0 +/- 0.5 volts DC.
• Overload Protection. The RED LED Indicator Light will illuminate and the inverter will automatically turn itself off when the continuous draw of the equipment being operated exceeds 1200 watts or the surge draw of the equipment exceeds 2400 watts.
• Thermal Protection. The RED LED Indicator Light will illuminate and the inverter will automatically turn itself off when the circuit temperature exceeds 150° F
1helpful
1answer

My 3000 watt aims inverter/30amp charger seems to work but the charger will not charge/transfer when I turn on the generator. Charging indicator will not come on. It does transfer the generator power

dear see that :
1- the range of voltage which inverter work between it for example 180-260 v
2- most small generator voltage reach more than 260V so the inveter not work
3-check the frequency of genaratoer if it not fix the inverter will mot work
0helpful
1answer

Can a battery charger for a camera, electric shaver, cell phone and cordless tool etc., be pluged into this power inverter without damaging those type of batteries.

It's not the battery that might be damaged. It would be the charger. What the charger does after it is damaged might be when and if a battery could be harmed.

Generally any AC powered device plugged into an inverter will work pretty well as long as the inverter is not putting out too poor of an AC voltage AND you don't exceed the inverter's rating.
0helpful
1answer

Lg 12000 btu air conditioner inverter is not working and the led 6 times.thanks

This alarm state is a CH 06 alarm.
Indication for the Indoor unit pipe temperature sensor (thermister) not plugged in or out of calibration.

This alarm will also occur when the unit gas charge is to low and the indoor unit temperature reached a temperature of -5°C for longer that 30 sec. It will switch the machine off.
Not finding what you are looking for?

708 views

Ask a Question

Usually answered in minutes!

Top Electronics - Others Experts