The conditions of the PM display consist of the codes of the setting mode (08) for "the setting value
treated as a threshold of the PM display", "the counter indicating the current number of prints and
driving time" and "the setting value which determines the display conditions".
08-6190: Setting value of PM counter [process unit (K)]
08-6191 : Setting value of PM time counter [process unit (K)]
08-5554 : Setting value of PM counter [developer material (K)]
08-5555 : Setting value of PM time counter [developer material (K)]
08-5562 : Setting value of PM counter [parts other than the PM parts of the process unit]
08-5563 : Setting value of PM time counter [parts other than the PM parts of the process unit]