Ch05 error in lg dual inverter unit need to change out door p.c.b
Ch38 error ...gas leak
Ch35 error gas less fill gas
Ch28 out door p.c.b wire loose

1 Related Answer

hvac1960

R Subramaniyam Iyer

  • 2133 Answers
  • Posted on Jan 03, 2011

SOURCE: indoor unit flashes 5 times. error code meaning?

E-5 -Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How do I resolve Error Code CH05 on my LG Dual Inverter window A/C?

On an LG Split System it is a communication issue between the outside and inside units. Try a power reset.

https://www.google.com/search?q=LG+LW2217ivsm+CH05+error

..
0helpful
3answers

My lg Split show Ch38 . repairman changed pipes between inside and outside panels and filled new gas . but after 3 weeks again show ch38 and don't work .

I just googled it and found an error code ch38 means indoor fan is not running, it's simple... Clean your filters people, it's not blowing enough air. Maybe it actually is the fan motor, it's too funked up now from not changing/ cleaning filter, or the wire came loose, I would put my electrical tester on the fan motor contacts and see if there's voltage during a call for cooling, if there's power to the fan but it does not run, your motor is dead, no amount of refrigerant will fix this so maybe call them back and have them do this
9_8_2019_2_07_24_am.png
0helpful
1answer

LG air conditioner model number LMN095HVT units keep on flashing with error code CH 46 and with no response at all. How can I fix it? Thanks for your help in advance!

ERROR CH46:
Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor.
0helpful
1answer

LG Inverter V model LMN096HVT air conditioner multi unit has error code 9. How can I fix this myself?

  1. How to fix lg with code CH05 - Fixya

    www.fixya.com/support/t12722126-fix_lg_code_ch05May 8, 2012 - Question about LG Air Conditioners. 2 Answers ... Hi, i've just moved into a house with a LG ART COOL C24AWR N80 inverter unit in it. Have just .... LG Inverter V model LMN096HVT air conditioner multi unit has error code 9.
0helpful
4answers

Indoor unit flashes 5 times. error code meaning?

E-5 -Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4
0helpful
1answer

LG dishwasher error code E1

E1 is a code that the dishwasher displays after detecting a leak. There is a sensor on the pan at the very bottom of the unit. Take the bottom front panel off, look under the unit at the hose coming off the pump and your fill line to be sure no water is dripping. Run the unit in a wash cycle while doing this if possible.
Not finding what you are looking for?

3,251 views

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

MattS1978

Level 1 Expert

7 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...