Does konica minolta 240f have a chip for reset

1 Answer

Norman Weimar

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Konica Minolta Master 7,035 Answers
  • Posted on Mar 25, 2018
Norman Weimar
Konica Minolta Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 09, 2009
Answers
7035
Questions
2
Helped
1911299
Points
11959

What do you want to reset???

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

5 Related Answers

Anonymous

  • 13 Answers
  • Posted on Sep 13, 2009

SOURCE: Reset Chip on Konica Minolta 8031 Imaging Unit

I can provide you with a programmer to reset the chip. They are only about $500-$700. Still interested?

Ad

Anonymous

  • 214 Answers
  • Posted on Oct 14, 2009

SOURCE: need to reset admin code for konica minolta c-350

Hello
press utility/counter - then under the counter "details" - stop 0 0 stop 01 - now you are in service mode, - stop 0 C, and there shold be admin pwd

Anonymous

  • 44 Answers
  • Posted on Nov 29, 2009

SOURCE: How do you do a hard reset on a Konica Minolta BH 600?

To recover/change the Administrator password perform the following;
1. Enter the Service mode.
2. Press STOP-0-CLEAR to enter the Enhanced security mode.
3. Enter Administrator Password setting, and enter new Password.

Anonymous

  • 1 Answer
  • Posted on Mar 09, 2012

SOURCE: i wanna know how to reset the maintenance time konica minolta bizhub 750

bizhub c252 how do you reset enter serial number

parsdesign_2

fraidoon shiravani

  • 3 Answers
  • Posted on Mar 28, 2012

SOURCE: Reset drum counter in Konica minolta bizhub c450,

Press utility/stop-0-0/stop-0-1/0C/no stop/end and exit setting.

It should work.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer
0helpful
1answer

How do i resolve jamming at the tray exit of Konica Minolta 240f

service all pick up and exit roller, or check the side door sensor, check of their spring returns.
0helpful
1answer

Konica minolta 240f error code 18 stands for what

https://printcopy.info/?l=en&mod=erc&brand=Konica-Minolta&model=bizhub%20240F&code=18


Konica Minolta bizhub 240F Error Codes

Quoting from the web link shown above:

Konica-Minolta bizhub 240F Error Codes

Exploded Views and Parts List Free!

Code

18

Description

Fuser Error
(The number indicates the detailed error code) 0 The fuser did not become to the main motor driving temperature in 50 seconds after printing started. 1 The fuser did not become to the paper pick-up temperature in 50 seconds after printing started. 2 The fuser did not become to the main motor driving temperature in 30 seconds after warming up started. 3 The fuser did not become to the warm-up finishing temperature in 30 seconds after the motor started driving. 4 A temperature of 250°C or higher is detected in a mode other than sleep mode. 5 The fuser does not warm after fuser error is solved and the power is turned OFF/ON. 6 A low temperature of 10°C is detected in 10 seconds after printing started. 7 A temperature of 190°C is detected in ready mode after printing finished.

Remedy

1. Turn on the power again, and verify the fuser warms up. If it does not, see step 4. 2. Check the contact between Fusing thermistor and Connect A PCB(P89). 3. Check the contact between Connect A PCB (P80C) and the main board. 4. Replace the Fuser. 5. After replacing the Fuser, verify the fuser warms up when the power is on. 6. Replace the main control PCB.
0helpful
1answer

I need help to clear error 18 on konical minolta 240f.

https://printcopy.info/?l=en&mod=erc&brand=Konica-Minolta&model=bizhub%20240F&code=18


Konica Minolta bizhub 240F Error Codes

Quoting from the web link shown above:

Konica-Minolta bizhub 240F Error Codes

Exploded Views and Parts List Free!

Code

18

Description

Fuser Error
(The number indicates the detailed error code) 0 The fuser did not become to the main motor driving temperature in 50 seconds after printing started. 1 The fuser did not become to the paper pick-up temperature in 50 seconds after printing started. 2 The fuser did not become to the main motor driving temperature in 30 seconds after warming up started. 3 The fuser did not become to the warm-up finishing temperature in 30 seconds after the motor started driving. 4 A temperature of 250°C or higher is detected in a mode other than sleep mode. 5 The fuser does not warm after fuser error is solved and the power is turned OFF/ON. 6 A low temperature of 10°C is detected in 10 seconds after printing started. 7 A temperature of 190°C is detected in ready mode after printing finished.

Remedy

1. Turn on the power again, and verify the fuser warms up. If it does not, see step 4. 2. Check the contact between Fusing thermistor and Connect A PCB(P89). 3. Check the contact between Connect A PCB (P80C) and the main board. 4. Replace the Fuser. 5. After replacing the Fuser, verify the fuser warms up when the power is on. 6. Replace the main control PCB.
1helpful
2answers

My bizhub 240f indicate replace toner, how can I clear it after refilling the toner?

There a chip on the toner unit once it used unless you reset chip, re filling it does not reset the chip go out and bye a new toner unit

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

0helpful
1answer

How do I cure Konica Minolta 240f lamp error message?

replace the lamp what is exposure lamp under the glass.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

0helpful
1answer

KONICA MINOLTA 240F

Yes sir.mam what about it?

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

Not finding what you are looking for?

791 views

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...