Just add developer in Cyan unit or check cyan charging.
machine will be ok.
Estimated abnormal parts:
• Fusing unit
• Printer control board (PRCB)
• AC drive board (ACDB)
• Fusing heater lamp /1 (L2)
• Fusing heater lamp /2 (L3)
• Fusing heater lamp /3 (L4)
• Temperature sensor /1 (TH1)
WARNING
• After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it may cause fire.
Solution
1. Check the connection between the rear side connector of the fusing unit and the main body side connector, and repair it if any abnormality.
2. Check the connector connection and the wiring between PRCB and the temperature sensor, and repair it if any abnormality.
3. Check the connector connection and the wiring between ACDB and the fusing heater lamp, and repair it if any abnormality. (Wiring diagram: Main body (1/3): 3-E)
4. Check the installation condition of the fusing heater lamp and ON/OFF with I/O, and repair/replace it if any abnormality. (Wiring diagram: Main body (1/3): 3-D)
5. Check the installation condition of TH1 and temperature of I/O, and adjust/replace it if any abnormality. (Wiring diagram: Main body (1/3): 3-F)
6. Replace TH1.
7. ReplaceL2, L3 and L4.
8. Replace ACDB.
9. Replace PRCB.
SOURCE: c6000 error code
Hi
Error C6000 is displayed when your machine fails to reach the correct temparature at a specific time.
This is a Fuser Unit Problem, try to reset it by--
First open top cover then turn on power.
press system menu/counter
arrow down to service
press and hold start, # then enter keys
arrow down to maintenance
press enter
arrow down to Sim 163
press enter
select execute
press enter
turn off power then back on
If the reset doesn't work then get your unit checked for fuser unit and fuser unit heat issues.
Please do rate this solution as FixYa and revert for further assistance.
Thanks
Rylee