Question about Precor Exercise & Fitness

1 Answer

Precor efx 546 version 1 Screen locked up and right bottom screen shows two upside down FF and diagonal lights going across the top and bottom of the main screen. Turning it on and off does nothing.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Precor Master
  • 1,594 Answers
Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad
  • 4234 Answers

SOURCE: Repairing JVC AV-27D202 27" TV

This is caused by a bad capacitor in the vertical circuit. If you can solder, you may be able to resolve this yourself. If you wish to attempt this repair, please update this and I will provide additional details and instructions.

Dan

Posted on Mar 21, 2009

dylanfinance
  • 3 Answers

SOURCE: Red line across top/blue line across bottom of screen

Adjust your convergence. Under menu I think its the last choice at the bottom of settings or picture menu

Posted on May 05, 2009

  • 8081 Answers

SOURCE: upside down and flipped numbers

Hello,
Press [CLEAR] to erase the screen. If that does not work reset the RAM
Press [2nd][MEM][7:Reset][1:All Ram][2:Reset][ENTER]. Then press [CLEAR].
If these steps fail, you should read the article.
Hope it helps.

Posted on Oct 30, 2009

  • 1 Answer

SOURCE: looking for repair manuals and error codes for

Could you please advice about ERROR 29 fo C956i/C966i treadmill.

Posted on Mar 04, 2010

  • 3 Answers

SOURCE: samsung a950 main screen display is backwards and upside down

My Samsung U700 had the same problem (display went back-to-front and colours all reversed and low-res.) It seems to be a problem with the flex cable (the cable between the main phone body and the sliding screen) wearing down and screwing up the data being carried between the display and the phone. Flex cables are cheap to buy and there's plenty of info online showing how to replace them yourself. Good-luck. Google: samsung u700 replacement flex cable

Posted on Aug 25, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Where do i find akeykpad for the procor 546


Fixya is unable to suggest sources for Procor parts.

Sep 01, 2018 | The Computers & Internet

1 Answer

Can I adjust the stride length?


Precor EFX 546 Version 1 Elliptical Trainer (Refurbished)

www.amazon.com > ... > Elliptical Trainers

Amazon.com, Inc.
Rating: 4.3 - ‎9 reviews
Working out on an elliptical can burn as many calories as working out on a treadmill. ...allowing you to go forward and backward, as well as adjust stride length to target ...The Precor EFX 546 allows you to stride smoothly while holding the ...

EFX® 546i Elliptical Fitness Crosstrainer™ ' Precor

www.precor.com/en-us/.../efx-546i-elliptical-fitness-crosstrainer-33
With the unique Precor CrossRamp® technology, users can alter the path of the EFX®546i between 13 and 40 degrees in both forward and reverse stride motions, cross ...Excellent stability and freedom of movement for users of all sizes.

FAQ - Precor


Dec 28, 2015 | Precor 546 Elliptical

2 Answers

Precor EFX 546 Version 1 making clunking noise


Someone needs to look at this as noise issues can be from anywhere and anything.

877-805-1030
Book An appointment

Feb 11, 2014 | Precor EFX 546i Elliptical Version 4

1 Answer

Precor efx 546 wobbles when raising incline


It may be either the front shroud is installed incorrectly or broken, or the corkscrew for the incline motor is bent. If it is bent, it would need to be replaced.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

Feb 10, 2014 | Precor Efx 546 Version 1 Lower Body...

1 Answer

Service manual 546


Repair Parts for Precor EFX 546i Ellipticals SPORTSMITH net

Please use your model and serial number to narrow down your search. In the middle of our Web page you will find the service manual for your machine.

Sep 03, 2013 | Precor EFX 546i Elliptical Version 4

1 Answer

How to repair a 546 efx precor


Assuming the buttons are working, the numbers change on the display, and the incline works, it may be the lower circuit board or the generator. If it is a very old unit, it may be the electromagnet or the data cable that connects the two circuit boards.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

May 08, 2013 | Precor Efx 546 Elliptical Version 2...

1 Answer

Efx time out after 7 sec


My Precor Elliptical EFX 546 Timer Stops After 7 Seconds, what is wrong? The most common cause for the Timer to Stop After 7 Seconds on a Precor Elliptical is NO RPM Feedback.
Knowing the status of the unit from its last use as well as the last service or part replacement is a great place to start.
Check the connection of the speed sensor to the lower board. Reset connection if necessary.
Check the magnet. The magnet is located on the user's right crank arm on versions 1 and 2 and the user's left on version 3. The magnet passes the speed sensor with each revolution of the crank arm. The magnet should be installed so that its south pole is facing the speed sensor. You can check the magnet polarity with another magnet that has marked poles or a compass. The north pole of the marked magnet or the south facing needle should be attracted to the magnet. Correct magnet installtion if necessary.
You may also check the spacing of the speed sensor to the magnet. The spacing should be 1/8" to 1/4". Adjust if necessary.


My Precor Elliptical Shuts Down After 7 Seconds what is wrong

Feb 02, 2012 | Precor EFX 546i Elliptical Version 4

1 Answer

My precor efx 544 has stopped recognising that i am using it. does not display strides or calories burned. any ideas?


My Precor Elliptical EFX 546 Timer Stops After 7 Seconds, what is wrong? The most common cause for the Timer to Stop After 7 Seconds on a Precor Elliptical is NO RPM Feedback.
Knowing the status of the unit from its last use as well as the last service or part replacement is a great place to start.
Check the connection of the speed sensor to the lower board. Reset connection if necessary.
Check the magnet. The magnet is located on the user's right crank arm on versions 1 and 2 and the user's left on version 3. The magnet passes the speed sensor with each revolution of the crank arm. The magnet should be installed so that its south pole is facing the speed sensor. You can check the magnet polarity with another magnet that has marked poles or a compass. The north pole of the marked magnet or the south facing needle should be attracted to the magnet. Correct magnet installtion if necessary.
You may also check the spacing of the speed sensor to the magnet. The spacing should be 1/8" to 1/4". Adjust if necessary.

Also see the following link for additional information.


Replaced Crank Arm on Precor EFX 546 and Display Doesn Work

Jan 14, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

Error 45 on Precor EFX 546 Elliptical


Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.

Precor Error Code 45

Jul 19, 2009 | Precor EFX 546i Elliptical Version 4

Not finding what you are looking for?
Exercise & Fitness Logo

Related Topics:

59 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

918 Answers

Ross Metcalfe
Ross Metcalfe

Level 2 Expert

135 Answers

Jose Pino

Level 3 Expert

563 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others