great analogy, sounds as if you have broken/stripped the tub block( its waht secures the inner tub to the outer tub) part number 389140, if you removethe agitator( a 7/16" bolt down the center of agitator) there is one more lock ring that isactually tightened down across the top of said "tub block"( usually need a specialty spanner wrench to remove, but have done it with a pipe wrench) after removing that lock nut the inner tub will release and the new tub block can be installed...
I would check all power to the tub. Is it plugged straight to a breaker, plugged into a GFCI, GFCI breaker in the master panel? For it to just stop altogether I would think something tripped.
×