No output from my generator

The generator starts but there is no output at the recepticles. Someone told me the unit may need to be remagnatized.

1 Answer

Greg Mills

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Master 497 Answers
  • Posted on Aug 09, 2009
Greg Mills
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Aug 09, 2009
Answers
497
Questions
2
Helped
168436
Points
1563

There is no such thing as "remagnatized" thats horrible and stupid advice. Your engine once started turns an alternator, which that produces electricity. Check all wiring connections first, if everything looks okay, you may need to replace the alternator.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I want to add a new circut to my fuse panel

Maybe I am not understanding you correctly. Most motor homes and RV come standard with a shore power recepticle. Are you wanting to add two sources of power? If so, you will need to really rework your wiring on the inside of your RV.
I have a generator on my motorhome and the generator plugs into the source recepticle when I want to run on generator, or I unplug to connect shore power.
4helpful
2answers

Have a onan 4500 watt generator on a bucket truck. i have no output at recepticles, can you help.

Onan units have a breaker switch on them that has to be in the right position or you get no power. Can't tell you for sure where it is on the 4500 but on the 4000 RV series it is tucked in behind the on board start switch
3helpful
1answer

How do you convert the (2) 240 volt outlets to one twist lock connector on a coleman powermate maxa 5000 er genset

Make an Umbilical recepticle adapter. Buy the recepticle install the recepticle in a 4" electrical BOX on a plate with two manufactured 3 prong power cords plugging into the 2 outlets and terminating at the new Box twist lock recepticle you made.
0helpful
2answers

My generator starts but it will not power the ac,

You dont say whether this is a newly developed problem or an unexpected one. Has it ever powered these items? If yes, then the unit needs to be checked out that it has not got bad brushes on the generators commutator.

1) check the wattage required to run each one. and compare it to the watts output of the Gen Set Microwaves are usually about 600-1000W and most generators of a portable nature are about 600W 25amps

A/C require a generator capable of 1KVA to power any decent size A/C other than a small window unit for a small caravan and certainly not a Mwave A/C at thye same time without showing signs of variant output( dimming)

Perhaps more information is needed here.

Please rate our help to keep the FREE service online++++Thanks for using FIXYA
1helpful
1answer

My Generator is putting out voltage on both the neutral side and positive side of 110 Volt recepticles. When hooking a meter to both sides (Neutral & Positive) it is showing 184 volts! It burnt up a...

Check the voltage with a meter in all the recepticles with your meter leads in the left and right slots on the plugs. Is that 184 volts AC there? If so, your gen has big problems with the voltage regulator. Let me know what you read. You can check the right slot of each plug to the round ground hole on the plug too, should be 120 volts there.


If you need further help, I’m available over the phone at https://www.6ya.com/expert/craig_3fa289bf857b1a3c

2helpful
2answers

The generator runs fine but will not give us any powere

Hello, Has this generator been setting for awhile or was it in use when the power ever came back on? Have you tried to repolarize it? To do this , Shut off the generator and unplug any cords or wiring from unit. Take a electrical cord that has a plug on one end and seperate the wires on the other end of cord. Strip the ends of the wire back about half an inch on each seperated wire.Plug the Male end of the wire into one of the 110V recepticles. Connect one of the ends of the wire you stripped back to the positive side of a 12 volt battery. Now with the other end of the wire you stripped back touch it to the Negative side of the battery for 1 sec and remove it. Unplug the wire from the recepticle and battery. Fire up the Generator and check the voltage! This repolarizes the unit and fixes most non generating problems from Non use and back feeding! Hope that helped! Rick
6helpful
3answers

Y generator starts but not putting out any power

plug in a electric drill into the generator. start the generator and let it idle. depress the trigger on the drill with the drill set in the forward position and by hand turn the drill in the opposite direction. it should excite the generator and start the drill
0helpful
1answer

Powermate 5000 low voltage under load

It could be a bad board but it sounds more like a bad set of brushes. If there is less than 1/4 inch of the brush (eihter one) left I'd replace both of them. I'd also check the diodes on the board with a DMM.

Regards,
Carl
0helpful
1answer

No electrical output or no electricity

Demand sams take it back, or give you a working one. They sold it, they need to handle their end of the deal. If they don't back there product, put it in the news.
1helpful
2answers

Ac wiring problem

as a general rule ,only if your ac was a window unit. aka a 120 volt unit . all other acs use 240 volt. a 120 leg and a 120 2nd leg to equal 240, so there is really no common. what kills acs with a generator is the lack of watts and starting torque. an ac (3 ton) and up needs a generator of 10000 watts minimum to handle starting trque. they also need a hard start kit to boost starting voltage.for god sake someone reply and tell me what a good job i am doing!!!!!!!as in grade the response to your question.
Not finding what you are looking for?

515 views

Ask a Question

Usually answered in minutes!

Top Coleman Electrical Supplies Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

john h

Level 3 Expert

29494 Answers

Are you a Coleman Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...