Lanier LD035: Copies were displaying a lot of dust. I replaced toner, drum , and developer. Hit copy sample. It work fine except smug on drum. I took drum unit out cleaned drum . Put it back in got error code 819 6261 0x64206469. Will I need to replace hard drive or simply replace drum to clear error? No technician available for my area.
SOURCE: Dust on Drum message after installinng new Drum
Dust on drum refers to as you correctly stated the wire, it carries a electric charge that transfers the image. If the wire gets contaminated the electricity dont flow right so dust on drum is desplayed, you drum cart is faulty, they are not repairable items, go buy another then claim new/old one as faulty from them. Um aH.
SOURCE: xerox 5305 copier excess toner
sounds like faulty drum cleaning blade,which is usually contained in the replacement drum module.I would be inclined to take the drum unit back where you got it (unless you replaced it with a second-hand one) 99% certain the problem is contained in that module
SOURCE: Aculaser C2600 "clean sensor" message
This is a common characteristic which arises from using improperly remanufactured toner cartridges.
Otherwise it is a bad Epson original one - which is highly unusual!
When the C2600 runs through its calibration it prints strips of each colour on the transfer belt which are sensed for density. You will get a "clean sensor message" if the reading for any of the strips drops below a certain value.
The first thing to do is to depress the clean sensor lever behind the front cover several times . If that doesn't fix it I would advise you to remove each cartridge in turn (go to reset menu and scroll down to change toner) and inspect the toner on the surface of the roller. If there is any form of "sheen" then you'll need to replace the cartridge.
It is possible to adjust the doctor blade if you know what you're doing but be careful as there are shims on each side. Loosening and moving the blade bar towards the roller slightly, refixing and then turning the side cog to rotate the roller can sometimes resolve problem. Not a good idea really unless you're in an emergency.
There are some good remanufactured cartridges and bad ones. If you want to avoid this buy genuine Epson cartridges - I know they're expensive but what does the down time cost!
SOURCE: Dust on Drum...
I had this problem too. I took out the drum and vacuum the drum with a vacuum cleaner ( no brush ) while at the same time manually rotate the drum cyclinder. It worked. After a month or two, you might have to do it again. But everytime, it solved the dust problem.
SOURCE: Konica/Minolta biz 350 C2557 after replacing DV unit and drum F8
tha minolta di3510 developer unit looks the same as the unit for the konica minolta bizhub 350 but the toner sensor in the minolta unit uses a different voltage range for the toner sensor and it will throw this code make sure you have the correct unit for this machine also you can try this
go back into tech rep mode and change these settings:
select tech rep choice mode
select printer tab
select atdc sensor gain
set the value to about 165
then back all the way out to the ready screen and power the machine off then back on and replenish toner in the user management screen.
65 views
Usually answered in minutes!
×