Alpine living air xl15 wiring schematics
SOURCE: Alpine Air Living Air XL15 not producing Ozone or Deodorizing. New plates
Confirm that the appropriate sections of the circuitry are powered up and drawing power; check the interlock switch action; toss it back to the maker because the Hi-V transformer or ladder circuit or sense or hold caps were (if testing proves) never quite functional.
SOURCE: xl15 sparking
Clean the contacts that touch the plates with Qtips and 70% or higher isopropyl alcohol and replace the plates. Sparking on the plates usually is a sign of a crack in the plate. The electricity is passing through the plate, creating an arc. The crack may be invisible to the naked eye.
SOURCE: Have a Living Air XL15 > everything works motor, fan, BUT .....
look through the front grill while its "on" you should see a glow from a neon lamp inside. If its not on chances are the circuit card is dead (should have about 350VDC plate voltage).
I have a used but good board if anyone needs one.
[email protected]
980 views