Waldimar Burger Posted on Nov 27, 2016

How do you reset compulsory inspection light on kipor kde6700ta generator screen modelkp308?

5 Related Answers

Anonymous

  • 169 Answers
  • Posted on Feb 23, 2009

SOURCE: Problem with a kipor 12 ta generator

Hi,
I just guessing here but it could mean that the oil pressure is too low.
I'd check the oil level first, then look for the oil pressure switch and temporarily disconnect it.

Regards,
Carl

Ad

Anonymous

  • 6468 Answers
  • Posted on Sep 08, 2012

SOURCE: kipor generator starts ok but will not provide electricity to apppliances

first check the circuit breakers if there ok the problem is inside like over heated parts

A

Anonymous

  • Posted on Sep 21, 2015

SOURCE: Iam looking to download a manual for a Kipor KDE

Try this link:

http://americanrvcompany.com/assets/images/Kipor/KDE5000ETA%20Operation%20Manual.pdf

Bill Boyd

  • 53816 Answers
  • Posted on Jul 22, 2018

SOURCE: KIPOR KDE6700TA no oil pressure, while

fill the sump to the correct level
check /replace oil level sensor system

nakhi2919

nakhi chouaib

  • 6 Answers
  • Posted on Feb 10, 2019

SOURCE: I have Kipor KDE6700TA Generator, while running it is showing a warning sign light of a "Tool"....what is this???? Thanx.

looks like you need to change the oil

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How fix L.H. Propect message? Kipor KDE6700TA diesel generator please.

190.3 volts isn't enough output for a 230 / 240 volt generator. It is protecting electronics that may be connected.

Specs show
Voltage (V) 115/230 120/240
https://www.google.com/search?q=L.H.+Propect+message%3F+Kipor+KDE6700TA+diesel+generator

..
1helpful
1answer

How can fix undercharge code on kipor kde6700ta diessel generator?

The "undercharge" code on a Kipor KDE6700TA diesel generator typically indicates that the battery is not receiving enough charge from the generator's alternator. Here are some steps you can take to address the issue:
  1. Check the battery: First, check the battery to make sure it is in good condition and fully charged. If the battery is old or damaged, it may not be able to hold a charge even if the alternator is working properly.
  2. Check the alternator: Use a multimeter to check the alternator's output voltage. The alternator should be producing around 14 volts. If the voltage is lower than this, the alternator may be faulty and in need of repair or replacement.
  3. Check the wiring: Make sure all wiring connections between the alternator, battery, and generator control unit are clean and tight. Loose or corroded connections can prevent the battery from receiving a full charge.
  4. Check the voltage regulator: The voltage regulator is responsible for controlling the alternator's output voltage. If the regulator is faulty, it may be allowing too little voltage to reach the battery. Check the voltage regulator with a multimeter and replace it if necessary.
  5. Check the fuses: Make sure all fuses in the generator's electrical system are in good condition and not blown. A blown fuse can prevent the alternator from charging the battery.
If you are not comfortable performing these steps yourself, it may be best to consult a professional technician to diagnose and repair the issue with your Kipor KDE6700TA diesel generator.
0helpful
1answer

Fix overtemp light on in kipor kde6700ta diessel generator

The overtemp light on the Kipor KDE6700TA diesel generator indicates that the engine is overheating. Here are some steps you can take to try to resolve the issue:
  1. Turn off the generator immediately and let it cool down. Check the coolant level in the radiator and top it off if it is low. If the coolant level is consistently low, check for leaks in the coolant system and repair them.
  2. Check the radiator fins for any blockages that may be preventing airflow. Clean the fins using compressed air or a soft brush.
  3. Check the fan belt tension and replace the belt if it is worn or loose. A loose belt can cause the fan to rotate at a slower speed, reducing the cooling capacity of the radiator.
  4. Check the thermostat to ensure that it is functioning correctly. If the thermostat is stuck in the closed position, it can cause the engine to overheat.
  5. Check the water pump to ensure that it is working correctly. A faulty water pump can reduce the flow of coolant through the engine, causing it to overheat.
  6. If you have tried all the above steps and the overtemp light is still on, it may be necessary to replace the thermostat, water pump, or other cooling system components. It's recommended to contact Kipor customer support or a qualified technician for further assistance.
Once you have resolved the issue, start the generator and let it run for a few minutes to ensure that it is operating at the correct temperature. Keep an eye on the overtemp light to ensure that it does not come back on.
0helpful
1answer

Kipor KDE6700TA Diesel Generator - 5,5 kVA. DIP Settings for US Model.

Question edited for clarity.
Question moved from Televisions

Easy way is to phone their Service Department.

https://www.google.com/search?q=kde+kipor+6700ta+dip+switch+settings

Kipor KDE6700TA Diesel Generator - 5,5 kVA

https://www.kipor-power.eu > Diesel Generators

Strong power. All diesel generator sets are equipped with KIPOR four-stroke engines, also the Kipor KDE6700TA Diesel Generator. · Advanced alternator winding.

KDE 6700TA - Diesel Generator »

https://www.kiporuk.co.uk > kde-6700ta-400-64-67

A new AVR(Automatic Voltage Regulator)delivers non-fluctuating power. Powerful KM186FAGET diesel engine. Optional electric starter.
0helpful
1answer

I have a kipor kde6700ta diesel generator that keeps blowing the main crankshaft seal on the generator side. What could be the problem. Martin in spain

Hi!
We can help. Check out our help centre to diagnoses the problem. https://www.generatorguru.com/need-help/

If you need more advice we can get you in contact with one of our Generator Engineers to guide you. We do not charge for this service and are happy to assist you throughout the repair.

Kind regards
The Generator Guru Team
Specialist Portable Generator Engineers & Parts Worldwide
www.GeneratorGuru.com
0helpful
1answer

Kipor kde6700ta error codes p 05

A diesel generator set for your reference: www.dieselgeneratortech.com
0helpful
1answer

Kipor Generator Diesel Kde6700ta P01 fault

Hope can say more details, so that i can provide a right methods. But if you want to see more faluts about diesel generator, here:
https://www.dieselgeneratortech.com/generator-sets/discovery-and-elimination-of-faults-of-the-control-system.html
Not finding what you are looking for?

831 views

Ask a Question

Usually answered in minutes!

Top Kipor Electrical Supplies Experts

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Kipor Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...