I HAVE A LINCOLD BARRIERE OIL FURNACE WHIT A AERO OIL BURNER 1.8 HP AND 2.8 AMP, I PLUG MY GENERATOR E2500 WHIT A 12-2 ELECTRIC EXTENSION, I DONT START MY FURNACE WHIT MY E 2500 HONDA.MY ENGINE RUN GOOD VOLT RANGE 110-120 VOLT. IMY FURNACE DO A FEW POWER OF FAN , I HAVE STOP GENERATOR FOR DONT DAMAGE TO MY ELECTRIC MOTOR. THANK MARIO CANADA.
The generator is not big enough to run what you want
it needs to be 3500w minimum or 4.5w to be safe
although it is stated at 2500 watts , in fact that is the peak load on electric motor start up and its continuous rating will be around 1.8 watts
all of this is clearly stated on the specs plate on the generator