Service Manual SHARP AR 5618 5620 5623 SME honestly I did not see this code in the owners manual but it should have a number you can call to ask how to clear it. I've noticed a few people have asked this question for this specific product but haven't gotten any answers. If you do find the solution please post it for people with the problem in the future :)
SOURCE: Sharp AR-M160 H4 error code
Clearing a trouble code on a AR-M160 is a little different than the AR160.
Try "#" "interrupt" "clear" "interupt" "1" "4" "start key"
This should clear the error. Even if you replace the fusion unit you will need this code to clear the error
SOURCE: sharp ar-m205 error code E7 11
U HAVE TO UPGRADE THE FIRM WARE BY ENTERING SIMULATION 49-1 THE VALUE IS d THEN UPDATE THE FIRM WARE IF U HAVE IT
SOURCE: sharp ar 405 u2-11 error
Content Counter check sum error (EEPROM)
Detail Checksum error in counter data area
Cause EEPROM defective
Control circuit hung up due to noise
Defective EEPROM access circuit on
PCU PWB
Check Check EEPROM for proper set-up
and To prevent the erasure of counter data
remedy and adjustment values, write down the
counter data and adjustment values by
simulation. (If there is a printer option,
execute SIM23-1 and note counter
data/adjustment values.)
Clear U2 trouble with SIM16.
Replace PCU PWB.