I have a Culligan water softener and noticed recently that there is a running water sound coming from the drain tube. There is no leaking, and the sound is almost like a constant trickle. It stops if we bypass the softener. any ideas? Culligan charges a fortune for a service call not to mention any parts. There are no error codes on the display and the owner's manual is not very helpful for troubleshooting.

1 Answer

RJ H2O

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Mentor:

An expert who has written 3 tips or uploaded 2 video tips.

  • Culligan Expert 311 Answers
  • Posted on Jul 03, 2011
RJ H2O
Culligan Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Mentor:

An expert who has written 3 tips or uploaded 2 video tips.

Joined: Jan 29, 2011
Answers
311
Questions
1
Helped
184566
Points
362

There is a problem with the piston/seal pack assembly pack in the valve. The seals get worn or some debris gets stuck and causes softener to run to the drain. The seal pack assembly needs to be replaced. If you are handy, you can do this. It takes about 1/2 hour for a novice.
Parts are only available from Culligan.
RJ

  • RJ H2O
    RJ H2O Jul 06, 2011

    The seal pack / piston assembly and retrofit kit should be less than $100.
    RJ

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

How do I access & clear debris in Backwash Restrictor in a Culligan Mark 80 Water Softener?

How to Troubleshoot a Culligan Water Softener
  1. Check the power supply cord if the unit is not operating. ...
  2. Check the circuit breakers or fuse box if the unit is not receiving power. ...
  3. Reset the timer if the house experienced a power failure. ...
  4. Check the bypass valves to make sure they are in the correct positions.
https://www.hunker.com/12333201/how-to-troubleshoot-a-culligan-water-softener
Apr 07, 2020 • Pool & Spa
0helpful
1answer

What causes culligan water softener tank to mak noise

The noise is normal during regeneration and draining.
You can manually set the regen clock to a different time.

There are Noises in My Culligan Water Softener Regeneration System Hunker
0helpful
1answer

How to. Bypass water conditioner of Culligan Estate 2

At the top of the conditioner, there is a tube running across the back of the head near the water line connections. the tube has push knobs on each end. With the blue knob pushed fully inward (knob up against the barrel of the valve / tube), water is routed through the water conditioner where it is softened. Water may be bypassed around the conditioner by pushing the red knob fully inward. Avoid "slapping" the valve when shifting from one position to another. see manual here: https://www.culliganmidmissouri.com/wp-content/uploads/2010/05/Estate2-Softener-Operating.pdf
0helpful
1answer

My water hose from my culligan n8 came off and water was poring out,..where did that come from and where do i reattach it? thx!

It depends on which hose you are referring to. If you are referring to the DRAIN it may have come off by the softener valve it goes back on the drain connection on the side of the valve (use a hose clamp). If it came off by where the softener drains it goes back into wherever the softener was draining (laundry tub, standpipe trap, floor drain)? If the hose came off by the connection for the salt tank it should be replaced. If you don't know, unplug the softener for now or it may flood again and call your local dealer.
RJ
RJ
1helpful
2answers

Leaking Culligan Water Softener at neck of tank, pipes might have gotten hitr since they are in the garage?Any idea what the troubles could be? If anyone has a manual, I would like some assistance.

I would suggest by-passing the system if the leak is substantial. Also make sure the leak is not coming from the main piston. Frequently leaks occur here, water runs down and collects around the top of tank before running down the side. Take the cover off, run the system through a manual regeneration and observe for any leaks. If the tank was hit it is most likely the leak is coming from connections between control and softener by-pass valve. If leak is coming from the tank and valve connection you will need to take the valve off to see if there is a crack at the tank threads. If so tank needs to be replaced. Here is a link for Culligan site that will have the manual for your machine.
http://www.culligan.com/en/service-and-maintenance/customer-support/owners-guide/

RJ
0helpful
1answer

It looks that water is leaking from the - Culligan water softner

Look down the tube (where the float assembly is) there should only be about 10-12" of water in there. For water to reach the brine tank over flow the tank would have to be 3/4 of water. Brine tanks can develop leaks over time if they were set on uneven ground or if any rocks or debris are under it. If there is no evidence of water running down the side of the brine tank this is the most likely cause. Also if it has been leaking for some time there will salt buildup around the brine tank. Check the water softener for any leaks also. At times a small leak from the softener will find it's way over to the brine tank and collect around the bottom of it.
RJ
0helpful
1answer

Culligan 01010091 (mark 89) softener will not auto

clean the drainage filter then it will work correctly again
0helpful
1answer

My culligan water softner just keeps running .

It is most likely running to drain. This is an indication that the seal pack is seized up, generally from a bent piston. You need to by-pass the softener and call Culligan for service. If you are handy there is a retro-fit kit available from Culligan to remedy this problem. It takes about 1/2 hr to install.
RJ
1helpful
2answers

Culligan medalist softener: Water continues to run thru drain line even after regeneration ends. What to do?

Its a most common problem with culligan seal pacs. If your softener is under 5 years old you have the worst softener on the market. Culligan was bought out about 5 years ago by a canada group. they changed every thing and nothing is made in the usa any more. You will have to buy a new one from culligan and pay over 90.00 for it. The old seal pacs lasted 15 years or more now your lucky if you get 2 years.
Nov 18, 2009 • Dryers
Not finding what you are looking for?

5,625 views

Ask a Question

Usually answered in minutes!

Top Culligan Measuring Tools & Sensors Experts

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66827 Answers

Steve Pack
Steve Pack

Level 3 Expert

7121 Answers

Are you a Culligan Measuring Tool and Sensor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...