Generac generator 7500 won't start, It was backfiring at an idle last time it was running.please help, can't keep paying $84/day for rental!!

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

Does generac gp7000e have throttle control?

Ronald,

Give them a hollar....

Spec sheet says idle control...full speed.

https://www.electricgeneratorsdirect.com/manuals/5626spec.pdf

Generac customer care center is here for you 24 hours a day, 7 days a week, 365 days a year.
1-888-436-3722
Speak with a customer representative.
0helpful
1answer

Generac 7500 watt generator take the wires off the brushes off and I get a 60 volt reading from the brushes and only 5 volts at the outlet can anyone tell me whats wrong

Please ask your supplier, they can answer your question.
But if you need more support or learn more about diesel generator set, maybe you can visit website: www.dieselgeneratortech.com, or contact [email protected] for inquiry
0helpful
1answer

I have a 16kW Generac Guardian Generator with a 200 amp house service RTS panel (installed 2007). Last night the power went out and the generator started but the unit did not switch to use generator

The problem with the repair service is another matter. Emergency generator and it's switch gear are there for emergency purposes. It has to be exercised periodically. The switch gear should have a toggle switch to simulate a power outage. the switch cuts power to the sensor sensing power from the utility company. This tells the switch gear that power was lost, start the engine and switch over to generator power. Run for a period where engine reached running temperature and switch back to stand by to shut down. Do this periodically, and be grateful the event was not a disaster. Think of your back up electrical system as the spare tire of your car and similar equipment and enjoy your investment. Good people brings you happiness, bad people brings you experience !.
0helpful
1answer

Generac troubleshooting

please send me more info about this generator I need a model number is this a natural gas or propane I have a neighbor that just had one installed I might be able to get some info from him to help you
0helpful
1answer

It back fires

If it backfires, check for manifold leaks, fuel mixture is too lean, timing is off, make sure it isn't spitting liquid into the cylinders and the LP is the right pressure, and the vapour coil is working
3helpful
1answer

I have a 3250 watt Kingcraft generator that won't

Always troubleshoot with new sparkplug. Remove the oil sending unit connection from the coil. The coil should work without any wires connected. Usually the only connections are oil sending unit that will short to ground when low oil condition and other wire must be kill wire to on/off switch. Use carb cleaner spray directly into the carb with air filter removed and choke off as fuel supply. Just a short spray and another short spray after a couple of pulls. If engine wants to start you will need to keep spraying cleaner for engine to continue to run. If engine wants to run, replace fuel with couple gallons of premium fuel to get it going. Hotter fuel will help if the compression is low. Good luck
0helpful
1answer

Generac 6500 1988 in R.V.Southwind Two things, both only occur in the morning or when cold (I am in So Cal so not that cold). First, when starting the generator from the dash board starter button the light...

See if there is an oil pressure guage on the dash. When you start the machine it probably has a low oil pressure shutdown which shuts the engine off when you release the start button. This is an interlock. Watch the oil guage and keep the start button engaged until you see oil pressure, release the button and it will continue to run at that point. Your second issue may be a function of the choke. If you are having to choke the engine to start, you may have to play with the choke position to keep from overfueling the unit which may cause it to stall and possibly backfire as it has to much fuel to be burned on the compression stroke, and is igniting occasionally on the intake stroke. Hope this helps. Marvin
Not finding what you are looking for?

445 views

Ask a Question

Usually answered in minutes!

Top Generac Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Brad Brown

Level 3 Expert

19187 Answers

Paul Bade

Level 3 Expert

1818 Answers

Are you a Generac Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...