Rewire for ?? High voltage motor wiring is L1-T1, L2-T2, L3-T3, T4-T7, T5-T8, T6-T9. Low voltage is L1-T1-T4, L2-T2-T5, L3-T3-T6. The motor protection overloads will need to be sized accordingly, to the motor's FLA ( full load amps) for the voltage used. The control needs to be looked at also, if there is a control transformer, the transformer needs to be wired or repaced for the new supply power voltage used.