Does not dry clothes well shuts off and display the code E65
Hello Becky;
My name is Peter. I am a retired field service appliance technician.
E65 = High limit thermostat trip count too high.
In other words, you probably have a restricted air flow problem. Your blower will shut down if your plugged up with lint.
In the back of your dryer is a hot air distribution manifold. At the bottom of the manifold is a small round connection. This is generally where the dyer air flow is blocked. There are only a few screws holding it on. Un plug your unit, remove the hot air distribution manifold, Clean the manifold and around the blower wheel. Turn the wheel by hand to ensure it is not stuck and free.
If this is not the problem, get back to me and we will talk about the high temperature thermostat.
Has anyone found a resolution? I have the same issues as Ron
I have made Dbl sure there is no air flow restrictions. I’ve had both panels replaced, heating element 3 times, thermal link 3 times as well. It works for about 20 minutes after a new thermal link is installed then throws the e65 error again.... idk what else to do. Please email mail me with suggestions...rongabbard @ gmail