Electrical Supplies Logo

Related Topics:

g
glenford gordon Posted on Dec 03, 2014

My kipor generator kde6700ta keep blowing a fuse each time i start up replace the fuse and the same thing happen

5 Related Answers

Ronnie Wilson

  • 1596 Answers
  • Posted on Jan 09, 2009

SOURCE: 2o amp starter fuse blows

This is a iindication of Hi resistance in your starter, thus starter May be on its way out

Ad

Anonymous

  • 169 Answers
  • Posted on Feb 23, 2009

SOURCE: Problem with a kipor 12 ta generator

Hi,
I just guessing here but it could mean that the oil pressure is too low.
I'd check the oil level first, then look for the oil pressure switch and temporarily disconnect it.

Regards,
Carl

4stevetaylor

  • 62 Answers
  • Posted on Apr 07, 2009

SOURCE: Kipor 3000ti generator, doesn't start, i checked

Drain carb bowl it could have water in the gas

Anonymous

  • 65 Answers
  • Posted on May 04, 2009

SOURCE: MAIN FUSE KEEPS BLOWING

there has to be something simple. check for broke/melted wires, wiggle test wires to make it blow fuse. how long does it take to blow fuse. does the fan go on.do you have to ride it to get it to blow?

spekgt

Filipe Mendonca

  • 60 Answers
  • Posted on Sep 02, 2009

SOURCE: My Honda ES6500 watt generator keeps blowing 15 amp fuse

Hi there .
In my opinion you should remove the starter and check the starter first . After you remove the starter get a good 12v battery and 2 wires and test the starter . Make sure to not invert polarity . After you touch the wires on the contactor (small solenoid on the side) see if the overrunnig (part with gears) comes out easy and with no obstruction . If the overrunning does not come out you could have a bad contactor (part # 31204-ZA0-003) or a bad starter (part # 31200-ZA0-701) .
Hope this help

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

How fix L.H. Propect message? Kipor KDE6700TA diesel generator please.

190.3 volts isn't enough output for a 230 / 240 volt generator. It is protecting electronics that may be connected.

Specs show
Voltage (V) 115/230 120/240
https://www.google.com/search?q=L.H.+Propect+message%3F+Kipor+KDE6700TA+diesel+generator

..
1helpful
1answer

How can fix undercharge code on kipor kde6700ta diessel generator?

The "undercharge" code on a Kipor KDE6700TA diesel generator typically indicates that the battery is not receiving enough charge from the generator's alternator. Here are some steps you can take to address the issue:
  1. Check the battery: First, check the battery to make sure it is in good condition and fully charged. If the battery is old or damaged, it may not be able to hold a charge even if the alternator is working properly.
  2. Check the alternator: Use a multimeter to check the alternator's output voltage. The alternator should be producing around 14 volts. If the voltage is lower than this, the alternator may be faulty and in need of repair or replacement.
  3. Check the wiring: Make sure all wiring connections between the alternator, battery, and generator control unit are clean and tight. Loose or corroded connections can prevent the battery from receiving a full charge.
  4. Check the voltage regulator: The voltage regulator is responsible for controlling the alternator's output voltage. If the regulator is faulty, it may be allowing too little voltage to reach the battery. Check the voltage regulator with a multimeter and replace it if necessary.
  5. Check the fuses: Make sure all fuses in the generator's electrical system are in good condition and not blown. A blown fuse can prevent the alternator from charging the battery.
If you are not comfortable performing these steps yourself, it may be best to consult a professional technician to diagnose and repair the issue with your Kipor KDE6700TA diesel generator.
0helpful
1answer

Fix overtemp light on in kipor kde6700ta diessel generator

The overtemp light on the Kipor KDE6700TA diesel generator indicates that the engine is overheating. Here are some steps you can take to try to resolve the issue:
  1. Turn off the generator immediately and let it cool down. Check the coolant level in the radiator and top it off if it is low. If the coolant level is consistently low, check for leaks in the coolant system and repair them.
  2. Check the radiator fins for any blockages that may be preventing airflow. Clean the fins using compressed air or a soft brush.
  3. Check the fan belt tension and replace the belt if it is worn or loose. A loose belt can cause the fan to rotate at a slower speed, reducing the cooling capacity of the radiator.
  4. Check the thermostat to ensure that it is functioning correctly. If the thermostat is stuck in the closed position, it can cause the engine to overheat.
  5. Check the water pump to ensure that it is working correctly. A faulty water pump can reduce the flow of coolant through the engine, causing it to overheat.
  6. If you have tried all the above steps and the overtemp light is still on, it may be necessary to replace the thermostat, water pump, or other cooling system components. It's recommended to contact Kipor customer support or a qualified technician for further assistance.
Once you have resolved the issue, start the generator and let it run for a few minutes to ensure that it is operating at the correct temperature. Keep an eye on the overtemp light to ensure that it does not come back on.
0helpful
1answer

Kipor KDE6700TA Diesel Generator - 5,5 kVA. DIP Settings for US Model.

Question edited for clarity.
Question moved from Televisions

Easy way is to phone their Service Department.

https://www.google.com/search?q=kde+kipor+6700ta+dip+switch+settings

Kipor KDE6700TA Diesel Generator - 5,5 kVA

https://www.kipor-power.eu > Diesel Generators

Strong power. All diesel generator sets are equipped with KIPOR four-stroke engines, also the Kipor KDE6700TA Diesel Generator. · Advanced alternator winding.

KDE 6700TA - Diesel Generator »

https://www.kiporuk.co.uk > kde-6700ta-400-64-67

A new AVR(Automatic Voltage Regulator)delivers non-fluctuating power. Powerful KM186FAGET diesel engine. Optional electric starter.
0helpful
1answer

I have a kipor kde6700ta diesel generator that keeps blowing the main crankshaft seal on the generator side. What could be the problem. Martin in spain

Hi!
We can help. Check out our help centre to diagnoses the problem. https://www.generatorguru.com/need-help/

If you need more advice we can get you in contact with one of our Generator Engineers to guide you. We do not charge for this service and are happy to assist you throughout the repair.

Kind regards
The Generator Guru Team
Specialist Portable Generator Engineers & Parts Worldwide
www.GeneratorGuru.com
0helpful
1answer

Kipor kde6700ta error codes p 05

A diesel generator set for your reference: www.dieselgeneratortech.com
0helpful
1answer

Kipor Generator Diesel Kde6700ta P01 fault

Hope can say more details, so that i can provide a right methods. But if you want to see more faluts about diesel generator, here:
https://www.dieselgeneratortech.com/generator-sets/discovery-and-elimination-of-faults-of-the-control-system.html
Not finding what you are looking for?

329 views

Ask a Question

Usually answered in minutes!

Top Kipor Electrical Supplies Experts

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66928 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Kipor Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...