This is model KEMS308SSS04
SOURCE: kitchenaid double convection microwave /
I'm guessing the model number would be KEMS308GSS0.
In some cases, this is a glitch that can be cured by unplugging it for 1 minutes, then resetting the clock.
In other case, it may be a bad keypad (membrane switch) or control board.
Please feel free to contact me directly if you need more help.
We're happy to help and we appreciate your thoughtful rating of our answer.
William E. Miller, AS-EET
[email protected]
http://www.microwavedisplay.com
SOURCE: Problem with the KitchenAid 30
well i will give you a link to suggestions that have already been made by other experts on Fixya. click here A. Unplug oven or disconnect power. B. Open the back panels and make sure the P6 and P2 connectors are fully inserted on the appliance manager and on the lower oven user interface board. - If they are not plugged in, plug in connectors and go to step F. - If they are plugged in, go to step C. C. Visually inspect all wires between P6 on the appliance manager and P2 on the lower user interface. - Make sure wires are not cut or pinched. - If the wires appear to be intact, perform a continuity check between P6-1 of the appliance manager and P2-1 of the user interface board.
otherwise,