Red Light My machine is only 4 days old. I got the snapping noise and was advised to clean the Truman Cell. I, first, cleaned the wires as instructed with a q-tip. When I went to reset "Check Collector Cell" as instructed, red light remained on blinking. I then, removed the Truman Cell and cleaned and dried it as to the instructions. Resetting the light does nothing. It still remains red and blinking.

  • zdunskijoe
    zdunskijoe May 17, 2016

    had this happen to mine, bent the two prongs going to the truman filter and it stopped blinking. might be a bad connection.

×

3 Answers

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 1 Answer
  • Posted on May 06, 2013
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Mayor:

An expert whose answer got voted for 2 times.

Joined: May 06, 2013
Answers
1
Questions
0
Helped
5088
Points
1

Slow blinking light means the unit is in DRY MODE.. flast blinking light means some sort of arcing or bad power supply..
if in dry mode let the unit run for an hour and it will stop blinking ..

Luke horan

Level 1:

An expert who has achieved level 1.

  • Contributor 1 Answer
  • Posted on Apr 23, 2022
Luke horan
Contributor
Level 1:

An expert who has achieved level 1.

Joined: Apr 23, 2022
Answers
1
Questions
0
Helped
5088
Points
4

I had problems resetting to turn off blinking red light,I bought a new truman cell and installed it today but after turning on oreck xl the red light started blinking red again.

I looked in every forum for ? solution but found nothing new.

I tried something new today,I tried resetting with power off then turned oreck xl back on and it's finally reset it,nomore blinking light

Ad

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

Scholar:

An expert who has written 20 answers of more than 400 characters.

  • Expert 70 Answers
  • Posted on Jun 28, 2009
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

Scholar:

An expert who has written 20 answers of more than 400 characters.

Joined: Jun 28, 2009
Answers
70
Questions
0
Helped
46731
Points
198

Sounds like a bad unit.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Can you add a prefilter to an oreck truman cell to grab the larger dust particles and decrease the zapping?a humidifier in the room helps but when the furnace is going it can still be often.

it should have a prefilter already on it. they have a screen looking filter that goes on the front of the cell. If you don't have one you need to get one. You should also have a charcoal filter on the back side of the cell, if not then you'll need to get one of those also, the charcoal is for odors and not for filtering dust. Putting any other type of filter in front of the cell will just be turning this into a filter type cleaner and will be defeating the purpose of the reusable Trueman cell. You may as well just buy a different cleaner if you don't mind buying new filters instead of cleaning the cell. I would recommend cleaning the cell every 2 weeks to keep it working properly. This will also keep it from snapping, if yours is snapping it's already too dirty and needs to be cleaned, if it's snapping right after it's cleaned then you have a plate that is arcing in the Trueman Cell, I have posted a fix for the ProSheild Models to stop the cell plates from arcing.
1helpful
3answers

Blinking 'Check Collector Cell' light

which model XL series do you have? There is obviously something shorted or arcing on the plates of the cell. look at the plates and see if they are laying flat and the wires are all still attached across the front of the cell. A loose, sagging, broken or bad contact on the end plates will cause the bad cell lights. clean off the area where the cell makes contact inside the unit. The metal strips that run across the ends of the cell make contact with the plates inside the cell and get their power from them, dirty contacts in any part of these contacts will cause the problem. Even a bad contact from the end cap to the plates inside the cell will cause this. Try wiggling the cell around, kind of push on it on edge to get the plates to shift slightly and clean the points where the plates touch the outer strips on the sides. Check for arcing with the lights turned off,
0helpful
1answer

Red light stays on after cleaning

which model, do you hear arcing or snapping sounds when it's running? Check wires that run along the inside front of the cell, loose, sagging or broken wires will cause this.
0helpful
1answer

A red light flashing with clean filter

bad connection on plates or wires that run along the front of the plates in the cell. If you hear snapping or arcing then its the plates shorting out, look for bent plates and broken wires or loose sagging wires.
1helpful
1answer

How do I clean the Oreck Air 7

Hi There,

Here's how you can clean the machine, and I have copied the link to the owners manual below for your convenience.

Cleaning
The Cabinet
You can clean the air purifier cabinet with mild, non-abrasive cleanser and a
soft cloth. IMPORTANT: Unplug the unit from its electrical power source.
Do not spray cleansers or furniture polish into the louver or grill areas.

Collector Cell
Indicator light is green under normal operation and flashes red
when the cell requires cleaning. To clean, proceed as follows:
The red "WASH CELL" light will flash or illuminate when it is
time to clean your cell. However, it is recommended that every four to
eight weeks or if snapping sounds become frequent, clean your
electronic air purifier. Your electronic air purifier is still filtering the air
when the red light illuminates. Cleaning your electronic air purifier is a
snap too... and a must for efficient operation.
1. Turn the unit off and unplug it from the electric power source. If wall
mounted, remove unit from wall.
2. Remove front grill by unscrewing the retainer screw under the grill on
the cabinet bottom. (fig. 1)
3251a7e.jpg
3. Pull the cell out of the cabinet by using the two small handles on the
front of the cell. (fig. 2)

4. Snap off the charcoal odor absorber from the back of the cell. Change
as necessary for continued odor removal. (fig. 3)
5. Slide off pre-filter. This can be cleaned with the cell and reused. (fig. 4)
NOTE: Handle the electronic cell with care. Damaged metal plates
and/or broken wires will cause the air purifier to malfunction. (Do
not wash charcoal odor absorber; it is disposable.)
Cleaning with Assail-A-Cell® Cell Cleaner:
6. Using Assail-A-Cell® Cleaner, thoroughly saturate the cell and prefilter.
Be sure to spray between each cell plate and cover every
surface. Allow product to soak for a few minutes, not allowing it to dry.
Rinse thoroughly with water. For extremely heavy deposits, repeat the
process.
IMPORTANT: Dry the collection cell thoroughly outside of the
air purifier before reinstalling it into the air purifier. Ensure
that all areas including corners and areas that may trap
water are dry before reinstalling into the air purifier. DO NOT
place a wet or damp collection cell in the air purifiereff1848.jpg
4. Snap off the charcoal odor absorber from the back of the cell. Change
as necessary for continued odor removal. (fig. 3)


e3ca384.jpg
5. Slide off pre-filter. This can be cleaned with the cell and reused. (fig. 4)


0781c8d.jpg
NOTE: Handle the electronic cell with care. Damaged metal plates
and/or broken wires will cause the air purifier to malfunction. (Do
not wash charcoal odor absorber; it is disposable.)
Cleaning with Assail-A-Cell® Cell Cleaner:
6. Using Assail-A-Cell® Cleaner, thoroughly saturate the cell and prefilter.
Be sure to spray between each cell plate and cover every
surface. Allow product to soak for a few minutes, not allowing it to dry.
Rinse thoroughly with water. For extremely heavy deposits, repeat the
process.
IMPORTANT: Dry the collection cell thoroughly outside of the
air purifier before reinstalling it into the air purifier. Ensure
that all areas including corners and areas that may trap
water are dry before reinstalling into the air purifier. DO NOT
place a wet or damp collection cell in the air purifier.

Here's the link to the owners manual for your Oreck Air 7:
http://www.oreck.com/includes/customer-service/owners-guides/pdfs/3323-3018-AIR7-Rev-H.pdf

I hope this was helpful to you. If this helped, please be kind and rate the repair, or leave feedback for me. Thank you,

Chris Jones
GoVacuum.com
14helpful
2answers

Ionic Breeze GP S1830 - makes a sizzeling noise

Funny you should post this when you did as I just finished reassembling my S1730.
Mine was making very loud noise, arcing violently, smoking slightly and would give a good shock when you touched the plastic covers(yes dirty plastic will conduct electric current).

1. Unplug the unit
2. Take the plastic covers off, front has four screws and back has snap at bottom, both slide up when loose.
3. Wash the plastic covers
4. take the light out and clean it with windex
5. Vacuum the inside, be careful of the two corona wires
6. Find the bead on each corona wire and while turning them slight so the edges scrapes the wire, move them back and forth to scrap the white power off the wires
7. scrape the cone shape plastic that the corona wires runs into, this build up is the primary culprit of the arcing which is the noise you hear. be careful of the corona wires again. I used an exacto knife and gently scraped it, sandpaper has been suggested elsewhere, once done scrapping, wipe down to clean any residue. The top cones are only part accessible, after cleaning mine the noise still persisted but acceptably lower than before. I think if you completely take apart the unit you can clean this cones better.
8. Reassembly is the same is opposite of disassembling.

Hopes this helps you.
1helpful
4answers

Collector cell light always comes on

Hi there,

We purchased one of these in April 2009. Same issue appeared with us. Cleaned the cell and the "clean collector cell" still stayed illuminated. Checked the manual and the trouble shooting section stated to hold down the "air revitalizer button" till the "clean collector cell" light blinks three times. After this operation the light went out and all was fine!!!! Hopes this clears your issue!

0helpful
2answers

Red light when swith on power button ?

cell is dirty, or you have a broken wire in the cell.
1helpful
2answers

Oreck XL® Professional

clean your cell. Allso check for broken or loose tungsten wires in cell.
Not finding what you are looking for?

5,098 views

Ask a Question

Usually answered in minutes!

Top Oreck Air Purifiers Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

vince

Level 3 Expert

2530 Answers

Are you an Oreck Air Purifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...