Precor Efx 5.17 Logo

Related Topics:

c
carli elliott Posted on Jul 06, 2014

Need to replace the AC Power Adaptor for my Precor Elliptical 5.17i. Would ANY 12VDC 120VAC work? Where can I purchase? Thank you for your help.

2 Answers

daf62757

Level 1:

An expert who has achieved level 1.

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 31 Answers
  • Posted on Oct 28, 2017
daf62757
Contributor
Level 1:

An expert who has achieved level 1.

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Oct 25, 2008
Answers
31
Questions
0
Helped
12800
Points
64

I had the same issue about 15 years ago. I looked up the model number on the old power pack and did a google search for it. I found another one and ordered it. Had been working ever since.

Carlos HernandezGarcia

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Welcome Back:

Visited the website for 2 consecutive days.

  • Contributor 12 Answers
  • Posted on Jul 07, 2014
Carlos HernandezGarcia
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Welcome Back:

Visited the website for 2 consecutive days.

Joined: Apr 22, 2014
Answers
12
Questions
0
Helped
1205
Points
32

You would need to check the amperage as well.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Where can I buy a simpletech 320GB BOM No: 96200-41001-057 power adapter? which power adapter do I need to purchase??

welcome to USA, we use our own adapters here, 120vac and special plug AC side.
where do you live country.?
simpletech 320GB BOM No: 96200-41001-05
they sell them on ebay, why not look there and buy it.
output 12vdc 0.4 amps or MORE.
center pin must be + output end.

any pack 12vdc like above works, over 0.4amps.
and AC end correct and if you have 240vac make sure the pack does that too.
0helpful
1answer

Precor efx546i error 30

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33
0helpful
1answer

ERROR 46

Precor Error 46, Low Battery Voltage (AMT12 Only) Probable Cause 1. Blown fuse in the positive battery wire of the AMT12 2. Faulty or poor connection on the battery or LPCA 3. Low or no output voltage from battery
Corrective Action
  1. Remove the power from the unit and move the lift fuse from the in line fuse holder on the positive battery cable
    • Measure the fuse with an ohm meter (multi meter), the fuse should read approximately 1 ohm or less
      • If the reading is significantly high, replace the fuse
      • If the fuse is open, refer to next solution before you continue
  2. Check connector of the battery cable for shorts or poor connections
  3. Enter the diagnostic program per procedure, P80 Settings or Accessing the P30 Diagnostic Software
    • Using the diagnostic program allows you to test the incline system without continuously pedaling the unit if you have an external power supply
      • Otherwise, you will need to continue to pedal the unit
    • Connect a DC voltmeter to the J3 connector on the lower PCA as follows:voltmeter common lead to terminal 3 (black wire) and voltmeter "hot" lead to terminal 2 (red wire)
    • Using the STRIDE HEIGHT Up and Down keys, operate the incline
      • The voltmeter should read about +12VDC when the incline is instructed to move upward and about -12VDC when incline is instructed to move downward
    • If either voltage measurement is significantly low, replace the battery
Precor Error 46 AMT12 Only Low Battery Voltage
0helpful
1answer

Why is my Precor Efx 546i elliptical showing an error message?

Precor Error 29, Excessive AC Input Current Probable Cause 1. The running belt and/or deck are badly worn.
2. Bad lower PCA.
3. Drive motor is shorted or de-magnetized causing a high power demand.
Corrective Action
  1. Check the amp draw using a clamp on AC volt-amp meter during loaded and no load conditions and compare values to a similar treadmill that is known to have a good running belt and deck. Replace the belt and/or deck if necessary. Don't forget, some units have a double sided deck which means it may be flipped over rather than replaced if it has an unused side.
  2. Test unit with a known good lower PCA. Replace lower PCA if necessary.
  3. Test unit with a known good drive motor. Replace drive motor if necessary.
Precor Error Code 29
0helpful
1answer

Error 30 on precor 546 efx

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33
0helpful
1answer

Error 30 problem for 556 precor elliptical

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33
0helpful
1answer

How to fix Precor EFX 5.17 error code 30

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33
1helpful
2answers

Belt replacement for precor efx 645 verison 1

You may have to purchase the belt from a Precor dealer in you area, if you don't have one then call Precor directly @ 1-800-347-4404 and they will help you. Most of these part have not hit the secondary market yet and Precor pretty much call the shots.
4helpful
1answer

Battery low

The battery is not fully charging to the 12v requirement their are a couple of screws that hold the side panels then rotate the panels counter-clockwise and they will come off. Take the battery leads off use a multi-meter the voltage on battery if it is below 12v then replace it. You may purchase this from a Precor dealer in you area if you don't have one then call Precor directly @ 1-800-347-4404 and they will help you.
Not finding what you are looking for?

290 views

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

920 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...