Anonymous Posted on Jun 09, 2014

Not cooling the compressor cycles on but it is not blowing cold air

  • Zach Thalman
    Zach Thalman Apr 21, 2015

    You may have a faulty compressor or you don 't have anymore of the coolant in the compressor. This sounds like you are going to need a new compressor. This is what happened to our refrigerator when it ran out. The motor would come on, but nothing was going on. http://www.assetaircon.com.au/maintenance.html

×

2 Answers

  • Official Brand Answer 2,267 Answers
  • Posted on Jun 12, 2014
Frigidaire
Official Brand Answer
Level 0:

Joined: Mar 18, 2014
Answers
2267
Questions
0
Helped
1289982
Points
2557

Good Afternoon Friend,

I understand that your Frigidaire air conditioner, model# FAC126P1, is not blowing cold air even though the compressor is cycling on.

First, check to make sure that the temperature sensing element is not touching a cold coil. This will be located behind the air filter. If it is, straighten the element away from the coil.

Secondly, try resetting your air conditioner to a lower temperature.

Lastly, the compressor shuts off sometimes by changing modes. Wait approximately 3 minutes and listen for the compressor to restart when set in the "COOL" mode.

I ask that you please follow up with a comment on the post, at your convenience, to advise if further troubleshooting is needed or if your dryer status has changed successfully. Hope this is helpful.

-Best Regards-
WP

Chadwick Mcconnell

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Jun 10, 2014
Chadwick Mcconnell
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: May 06, 2014
Answers
1
Questions
1
Helped
207
Points
1

Check to see if it has excess water draining out. It might be clooged somewhere.

Ad

4 Related Answers

Anonymous

  • 1 Answer
  • Posted on Jun 29, 2008

SOURCE: No cold air

if unit is more than 5 yrs old dump it!!! most frigidaire models just dont last...that is why they are so cheap...get it???

Ad

terryboonstr

  • 45 Answers
  • Posted on Jun 07, 2010

SOURCE: my ac is not blowing cold air

The unit may be low on refrigerant. There is probably a low pressure switch in the unit to protect the compressor so it wont turn on and get damaged beyond repair. You can take it to your local appliance repair shop and have it looked at. I would get a quote on repair first. Most of the time it is cheaper to buy a new unit than it is to pay just the labor to have it repaired.

Ralph Cronenberg

  • 449 Answers
  • Posted on Sep 09, 2010

SOURCE: I have a frigidare FAM157S1A Air Conditioner, when

your compressor motor is no good Time to replace unit

Anonymous

  • 1654 Answers
  • Posted on May 29, 2011

SOURCE: Air conditioner isn't blowing cold!

You will need the condenser coils repaired before you can charge it. These come from the factory sealed and they should not ever need a charge unless you have a leak. The hissing sound is more likely air in the system being pumped by the comressor and it is coming out a hole in the coils.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

Amana Wall unit blows cold air before heating

The cold that you describe may be just unconditioned air? If you are certain you can hear the comp operating for a couple of minutes, and then the heat starts, I would guess it is a reversing valve issue if it's a heat pump and it probably is. Or the control board acting up. I've had a lot of issues with the boards in the Amanda PTAC units. I can't remember how to configure it, but if you Google "Amanda ptac configuration", there is a lot of info online. May try a reset method first. Hope this helps!
1helpful
4answers

2004 sebring air conditioner stops and starts

Low freon will cause the compressor to short cycle, when the compressor runs the pressure in the low line is pulled down and the low pressure switch turns it off. Not running the pressure builds up and turns it back on. In the old days there was no low pressure switch, with no freon to carry the oil the compressor was destroyed.
1helpful
1answer

My air conditioner is only blowing cold air on the passenger side. Both sides blow but only passenger side is cold. My compressor also short cycles on the low pressure safety. What would cause that?? I...

Hi, the reason for this is the location of the evaporator core, its on the passenger side, a low charge will cause the side nearest to core it to cool more. Your cycling of compressor concures with this scenario. Recharge system to specifications.
0helpful
3answers

I have a Artic Air White Reach In Freezer. It is not blowing cold air from he top where the cold air comes in. Freezer was at 60 degrees F. I turned the defrost switch to make sure it wasn't in...

Is the freezer itself getting cold.To blow cold air.the freezer should get cold/friezed.the cold air blows from freezer to fridge side.first the freezer side gets cold, then when the freezer side gets enough cool to its set cooling temperature, at that time the defrost cycle starts.In defrost cycle the fan in the freezer starts running and the cool air from freezer starts going to fridge side.There is a ventilation passage between fridge and freezer from where this cool air passes.---------------- If in your case, the freezer is getting proper cold, but its not blowing cold air from freezer to fridge, then possibility is that, there is a blockage in ventilations.But if ventilation its clear, then its defrost problem.First try manual defrost reset procedure. The procedure is as follows: ---- First unplug the unit from main power outlet. Then empty whole unit completely. Then keep both the doors open. Wait for 24 hours. All the ice collected on the coils and in the freezer section will get melted. Clean the water from the sections. Then Connect the power cord of the unit to main power outlet after 24 hours/.Then set the temperature to normal in both fridge and freezer section. It will take near to 4 hours to get run in its proper cooling cycle. Then check, if the problem returns again. Then its defrost board problem. ------------------------- BUT if in your case, the freezer section itself is not getting cold, then the problem is compressor related.The compressor is the part which cools the freezer frost.In the compressor, there is a refrigerant to cool the freezer.If the compressor gets weak or the refrigerant gets low, then it will not cool the freezer, if the freezer is not cool then it will blow warm air from freezer to fridge, in defrost cycle.In that case, the compressor is faulty and its the cause of problem.------------ So you will have to first check , that is your freezer getting cold or not.as per that you can start the troubleshooting.------------------

You can get required parts from from online sites like: --- www.repairclinic.com or from searspartsdirect online site. --------- This should help.Thanks.Helpmech.

0helpful
1answer

My 2002 Expedition air conditioner will sometimes blow hot air and others cold air

I would check the following possibilities:
1. Is compressor clutch working? - You need to do this when the ac is blowing hot air only - locate compressor drive pulley on engine - rubber belt wraps around it. Start engine and set to max ac. When the ac is blowing hot air, look at the center of the compressor drive pulley using a good flash light - watch it for a while, it should be spinning with the pulley - this means the compressor is engaged. If not, the compressor is not engaged. If your ac is blowing hot air, then the compressor should be engaged and running (trying to cool). If it is not engaged, then your compressor clutch is probably going out. Could be low voltage to clutch, but more likely the clutch is worn out and only working some of the time. Note: if working normally, the compressor clutch will engage and disengage in cycles- but the air should always be cold. If clutch is bad, compressor would need to be replaced (sold as one unit). This is tricky to diagnose and could take some time - you need to do it when ac is blowing hot air but set to max cooling.

2. Low on refrigerant or refrigerant has moisture in it? If your ac blows cold initially after being off for a while, then heats up, and continues to regularly cycle back and forth between hot and cool air, then the system may be low on refrigerant or the refrigerant may have moisture in it that is freezing and restricting refrigerant flow. An a/c shop can check refrigerant level and even replace refrigerant if moisture is suspected.

Could be other issues, but I would start with these.

Good luck
1helpful
2answers

Air conditioner doesn't blow cold air. Continues

If the a/c fails to continue to blow cold there could be a few problems you can look for. First once you activate the system check to see if the compressor kicks in. You will hear the compressor humming . Once the a/c quits cooling go and see if the compressor is still running. If its not running its probibly gone into thermal overload (compressor overheated). If that is the case then you need to check to see if the coils are icing up if they are icing up then the problem is with 1) air flow restriction filter dirty, coils dirty simple repairs there replace filter, clean evaporator coil with a coil cleaner that can be purchased at a home repair store cleaning the condensor coil the same. 2) system is low on freon in which case the system will need to be recharged. Also, If you have a digital thermostat replace the batteries that may also be of some help. Good Luck on repairs



Dave
0helpful
1answer

AC doesn't blow cold air, but refrigerant levels

The low side pressure seems ok the high side would help,Is your compressor cycling and is the air coming out even slightly cool?slight over charge cold effect cooling ability.I wish I could be more help. I will have to think about this one.maybe you could make sure your temp.door is actually in the commanded cold position.
0helpful
1answer

99 F250 diesel: A/C blows cold (fully

I think what happens is that you're burning out the compressor. If you got the windows down while you're blowing the a/c? it's working over time which is why they have two cycles. The image that displays the circle motion is meant for the windows to be up and the charge will last longer and with the windows down...click the one that shows outside air coming into the car. It might not be as cold as the other option but at least you'll have some cool air while you're at it.
Not finding what you are looking for?

217 views

Ask a Question

Usually answered in minutes!

Top Frigidaire Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Frigidaire Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...