Exercise & Fitness Logo

Related Topics:

A
Anonymous Posted on May 22, 2014

How to fix error code 50 on EFX 5.21i? - Precor Exercise & Fitness

2 Answers

LilyHart

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Welcome Back:

Visited the website for 2 consecutive days.

  • Contributor 4 Answers
  • Posted on Apr 25, 2018
LilyHart
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Welcome Back:

Visited the website for 2 consecutive days.

Joined: Apr 18, 2018
Answers
4
Questions
0
Helped
7652
Points
10

Sometimes outdated software prevents from using computer smoothly. Therefore, the error 50, as well as other errors might occur, due to the outdated software or system. For this reason, you should check available updates and install them:
Go to App Store.
Click Update icon.
If there are any available updates, click Update All button.
In case, all the above steps will not work to fix this Mac error code 50, then you should Check this URL.
https://www.errorsolutions.tech/error/error-code-50/

Sportsmith LLC

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Precor Master 920 Answers
  • Posted on Jul 28, 2014
Sportsmith LLC
Precor Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Apr 23, 2014
Answers
920
Questions
0
Helped
514762
Points
111994

Precor Error 50, Too Much Brake (Magnet) Current Probable Cause 1. Shorted or damaged wiring between the lower PCA and the eddy current magnet is the most common cause for this error.
2. Bad eddy current magnet.
3. Bad lower PCA.
Corrective Action

  1. Thoroughly inspect the eddy current wiring and connections ensuring that the wires are not shorted to the frame or shorted together. Repair or replace damaged wiring as necessary.
  2. Disconnect the wires from the eddy current magnet. Using an ohm meter, check for approximately 100 ohms across the eddy current magnet terminals. If the reading is considerably low, replace the eddy current magnet. Measure ohms between each eddy current magnet terminal and the frame ground. You should have no resistance between the eddy current magnet terminal and the frame ground. If resistance is present this would indicate a partial short, replace the eddy current magnet.
  3. If the eddy current magnet wiring and the eddy current magnet are both good from the above tests, replace the lower PCA.
Error 50 Too Much Brake Current on Precor Cardio Equipment

Ad

1 Related Answer

Anonymous

  • 3 Answers
  • Posted on Mar 10, 2013

SOURCE: My Precor EFX 5.17i elliptical trainer keeps displaying "Error 40" even when I turn it off and back on. How can I fix it?

try puting in new baterrys

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Reset the error code on a precor elliptical

Not familiar with an error 400 - and error 40 is an elevation error - it needs to be addressed(fixed) cannot really be reset otherwise. Check connections and fuses first. If it was recently put together, make sure the data cable was not pinched. If it is battery operated, an error 40 can occur when the battery is low.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

0helpful
1answer

Precor elliptical

Precor Error 50, Too Much Brake (Magnet) Current Probable Cause 1. Shorted or damaged wiring between the lower PCA and the eddy current magnet is the most common cause for this error.
2. Bad eddy current magnet.
3. Bad lower PCA.
Corrective Action
  1. Thoroughly inspect the eddy current wiring and connections ensuring that the wires are not shorted to the frame or shorted together. Repair or replace damaged wiring as necessary.
  2. Disconnect the wires from the eddy current magnet. Using an ohm meter, check for approximately 100 ohms across the eddy current magnet terminals. If the reading is considerably low, replace the eddy current magnet. Measure ohms between each eddy current magnet terminal and the frame ground. You should have no resistance between the eddy current magnet terminal and the frame ground. If resistance is present this would indicate a partial short, replace the eddy current magnet.
  3. If the eddy current magnet wiring and the eddy current magnet are both good from the above tests, replace the lower PCA.
Error 50 Too Much Brake Current on Precor Cardio Equipment
1helpful
1answer

"stuck key" message on efx 546i, will not engage, already replaced batttery

Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05
0helpful
1answer

What is error 50 on the precor efx546

Error 50, Too Much Brake (Magnet) Current
The problem maybe lower board related or improper signal is being translated Call Precor @ 800-347-4404
0helpful
1answer

What is error 50 on the precor efx546

Precor uses the same error codes for all of their units. Error code 50 is for excessive brake (eddy current magnet) current.
1helpful
1answer

Error 45 on Precor EFX 546 Elliptical

Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.

Precor Error Code 45
Not finding what you are looking for?

2,103 views

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

920 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...