MINE YOU THAT IF THIS PROCEDURE DOES NOT WORK DO NOT RESET GAIN YOU ARE DEALING WITH THE FUSER IT CAN CATCH ON FIRE THAT WILL RUIN A PERFECTLY GOOD DAY!!!!!!!! have tech come out replace the fuser
1. Turn OFF the Main Power Switch.
2. Turn Main Power Switch ON while pressing the Utility/Counter key.
3. Touch [Trouble Reset].
4. Check to make sure that [OK] is displayed and the it has been reset.
5. After turning off the Main Power Switch, turn it on again more than 10 seconds after
and check if the machine starts correctly.
Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f
SOURCE: konica minolta bizhub 350
• The Fusing Roller Sub Thermistor does not
detect the required temperature within 30 sec.
after a warm-up cycle has begun; therefore, the
copier does not complete the warm-up cycle.
• The temperature of the Fusing Rollers does not
reach the required level even after the set period
of time has elapsed during a warm-up cycle.
1
Check that the H1[ fuser lamp] comes on when the Main Power
Switch is set to ON, and correct or replace as necessary.
- -
2
Check that the H2 comes on when the Main Power
Switch is set to ON, and correct or replace as necessary.
- -
3
Check the installation of the TH1 and the TH2, and
correct or clean as necessary.
- -
4
Check the operation of the TH1.
Remove CN80 (4P), and then check that the resistance
across CN80-2 and -3 on the Thermistor is
infinity.
- -
5
Check the operation of the TH2.
Remove CN81 (4P), and then check that the resistance
across CN81-2 and -3 on the Thermistor is
infinity.
- -
6
Check the continuity of the H1.
Correct or replace as necessary.
- -
7
Check the continuity of the H2.
Correct or replace as necessary.
- -
8 Change PU1 - -
9 Change PWB-A
SOURCE: konica minolta bizhub C252 printer Problem
Is anyone else having problems getting Konica to stand behind its products.
SOURCE: when I turn on the machine (bizhub c300) error
This is a fuser related code.
To reset the code, please do the following
1. Turn OFF the Main Power Switch.
2. Turn Main Power Switch ON while pressing the Utility/Counter key.
3. Touch Trouble Reset.
4. Check to make sure that OK is displayed and the it has been reset.
5. After turning off the Main Power Switch, turn it on again more than 10 seconds after
and check if the machine starts correctly.
Good luck
SOURCE: bizhub C252 factory reset
if you mean to initialize the machine then go to service mode, then go to system 1, from there you can initialize the machine settings to factory settings.
SOURCE: I have a Konica Minolta Bizhub c252 what is code c-5102
C-5102/5103 - Main motor failure.
Check the motor connector,the drive coupling or the mechanical control board and DC power supply unit.90% mechanical rpoblem.
Sir/mam check the right side door that you open to remove the image unit check that the two latches that hold the door close are OK especially the rear one. Close up. To reset. On the right side of the machine just below the scanner section (The part with the big glass) is a cover next to where you connect the Ethernet cable. Remove the cover with the machine on use a small screw driver and gentle depress the small black switch the machine is going to go thru some screens when you see the screen with the copiers on it to the left on the screen in the middle you will see a "." when that is displayed press 3. Code will come back but now press the Utility/counter button should see button that say maintenance mode press that see trouble reset press that machine again will go thru warm up procedure will see the "." DO Nothing! Should go to "Ready to Copy" if the code comes back have a technician look at it DO NOT CONTINUE TO RESET the code is for the Hot Part called the FUSER. Can catch on fire! That will ruin a perfectly good day!!!!
Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f
283 views