SOURCE: Healthrider S300i Have 120V to AC1 & AC2 on
Make sure
you have power in the wall outlet by plugging in a lamp, etc. into the same
outlet the treadmill is plugged into to test. Plug it in the exact same
receptacle. Sometimes in an outlet one receptacle will work and the other
won't.
Make sure
any breakers are fuses that may have tripped or blown have been reset or
replaced.. Use the same type of fuse. Changing the value of the fuse can be
dangerous or cause a fire.
Make sure
the power switch is turned on and the safety key is inserted into the console
if you have a safety key.
Look for
any test lights on the power boards beneath the motor hood. Use caution when
removing the motor hood because you may still have electricity in the motor
area even if the treadmill is unplugged.
Test for
a motor control failure. Typically if you have a failure, the treadmill will
continue to turn on and operate normally until you try to input speed. If the
treadmill operates on what we call a closed-loop system, it will give you some
type of error message. If it operates on an open-loop system, the computer will
run normally but the motor will not turn.
If you
have a multimeter, you can test to make sure you have DC output from the
controller spades. First make sure you have 120 VAC going in to the controller.
On most controls, you can use a linear taper potentiometer or jump the W and H
circuits of the control with an insulated wire or insulated pliers and apply AC
voltage. The DC output spades should output DC voltage if the control is good.
The motor
can be tested by using a simple DC cordless drill or lantern battery. MAKE
SURE TO USE A DC POWER SOURCE...DO NOT USE AN AC POWER SOURCE OR YOU CAN RUIN THE
MOTOR.
SOURCE: I have a HealthRider S300i
you can try to rent a set at AutoZone. when you return it they will give your money back. try standard and metric. depending on manufacturer of treadmill.
SOURCE: my healthrider s300i softstrider treadmill
1)See if flexible cable from display board is bending to lower board.
2)main motor board is faulty by worn deck belt.
3) burn motor faulty.
4) adjust the Potentionmeter from the motor (incline).
5)Defective gear in inclination motor.
See the block diagram
SOURCE: I have a Healthrider Softstrider
1) you have 3 problems: mechanical+ electrical + electronic.
2) adjust the tensions from deck bel + drive belt motor
3)test the main motor without load and see what happen.
4)test the main motor board and see what happen.
see block diagram