I have a three year old Hobart. I am not sure where the model no. is. It is an under counter model that takes sanitizer. There are three red LEDs for soap, rinse and sanitizer. The sanitizer LED blinks, indicating low sanitizer, but there is plenty of bleach in the bottle. Thanks,
Glen
Look on the top edge of the door to find the data plate. It sounds like an SR24, if the leds are on the left of two temp gauges. If your sanitizer pump has a tired silicone tube that is flattened from use, it will not draw chemical. if you have an air bubble in the sense board at the back, it will think you have run out. If you have changed the type of chemical or diluted it, the board will need recalibrating to suit. Put some sanitizer in a small vessel with the pickup tube and monitor the amount delivered. Usually one is looking for 50 ppm solution of bleach and rinse water.( test with litmus paper) If you have an SR24H with a booster, you don't need bleach sanitizer and holding the sanitizer button will turn the sense off.