I have a p500b printronix cfx logic card which is showing hammer bank fault what i have to do ???
SOURCE: I have T6218 printer and
If you haven't fixed? If you don't get Hammer Voltage 2 error immediately, then sounds like your blower underneath the ribbon deck which keeps the hammerbank kewl is not working... Be careful but you can get shelf or cart about printer height and remove the ribbon deck with ribbon & cables still connected from the print. Rotate and sit it on the shelf or a cart. Start printing and see if the black blower(in the middle with a little black air duct going to the hammerbank) is working.
One other thing their's qty 7 hammer coils per hammer bank, if you have replaced the 1st 2 reading from left to right with hammerbank installed in printer, then you have qty 5 more which 1 of the 5 left is causing Hammer Voltage 2.
Have any other ??? feel free to call at x311
Toby
SOURCE: Printronix p5205B
Hello,
Check to make sure that your ribbon is not folding on the left. Have seen many printers with that ribbon guide off a little causing that issue.
If this is not the case you can try adjusting your platen. If that doesn't work, Shuttle are know to go out. They have coils behind the frets which lose resistance over time. If this is the case the shuttle will need to be replaced.
If you have any questions or need parts or printers please contact me we are an ASR for Printronix. We also offer free technical support.