I am trying to install Cooper Wiring Device to a fluorescent light. There are three wires, not two as indicated in the instructions. Also, there are two copper wires and a green one; no black .

1 Answer

Gil Shultz

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Master 3,464 Answers
  • Posted on Apr 29, 2014
Gil Shultz
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Nov 26, 2009
Answers
3464
Questions
1
Helped
731894
Points
11104

I am a bit confused however I know a fluorescent light needs a special dimmer and ballast. It sounds llike you do not have the correct parts.

2 Related Answers

Anonymous

  • 76 Answers
  • Posted on Jun 27, 2009

SOURCE: need to know wiring diagram for cooper single pole lighted switch

well lets see on one side you should have two brass screws that would be to interupt your lead to the fixture then you either have a brass and silver screws on the other side or you have black and white wires the black or brass is always hot the silver or white is neutral does that answer your question if not hit me back with a description of what your switch looks like

Ad
A

Anonymous

  • Posted on Dec 08, 2010

SOURCE: Cooper Industries Cooper Wiring 274W Switch and

Switch-plug combo:
bare ground goes to green screw
dark screw goes to hot from breaker
silver screw to neutral
brass screw goes to load (light)

Add a comment any time
You are replacing single pole light switch?
Single pole switch has 3 wires: black and red and bare copper

New device has 4 different colored screws: green, dark, brass, silver
Bare copper goes to green screw.
Black wire goes to dark screw
Red wire to brass screw
Nothing on silver screw for a moment. Test circuit and make sure light turns on-off.
If lights works, then good so far.

Now let look at silver screw. Neutral wire has to connect to silver screw.
In back of your electrical box are white wires twisted together and covered with wire nut.
These are neutral wires.
You must connect another short piece of insulated wire to these neutral wires and run that wire to silver screw.
The neutral wire will complete circuit to receptacle.
If you do not have neutral wire, then receptacle will not work in that box without additional wiring.

Hook up neutral wire to silver screw.
Now turn on power and click switch again.
If circuit breaker trips, then reverse your red and black wires.
Otherwise this should be correct wiring.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Wiring instructions for Cooper TR7730 combination wiring device

Hi Dave,
Great description, but you never mentioned what you are
using the switch for. I can explain in detail, but I need to
know if the switch load is coming from the same cable or
an additional one.
0helpful
1answer

Cooper wiring devices 390-6107xx-eg1d wiring diagram

This is the Cooper product #6107; Standard Series Occupancy Sensor, 3-Way, 500W/400W, Incandescent, Halogen, Fluorescent Rapid Start Ballast.

Do NOT use to control light fixtures with CFL or LED lamps!

Connect this switch by using the diagram for the #6107 Single-Pole or 3-Way (match your existing switch) linked below.

https://objects.eanixter.com/PD365967.PDF
0helpful
1answer

Switch doesn't work

Because the switches have electronics in them the ground wire may be very important to give it a full 120 volts to be able to run. Also double check your lighting, these dimmers are likely for incondescent lighting only (light bulbs). A compact fluorescent or some other lighting may blow the switches. If your lights are led they may not have sufficient resistance so that the dimmer knows that you have any lighting at all. Fluorescent lighting has to high a capacitive reactance and or inductive reactance. Halogen or other lights may cause troubles too. Check the directions on your switches to see if they were for incondescent only or for fluorescent only etc. Also modern bulbs don't seem to screw far enough into the sockets because of their fat necks that bottom too soon. You may have to turn off the power then put your finger inside to bend the bottom contact up enough to touch the bulbs.
0helpful
1answer

I have a cooper comb devces how do i wire i want switch to control the plug

The Cooper combo device requires neutral wire to energize the outlet.
To control outlet with switch, the Hot side of device must have break-away fin.
Remove break-away fin.
Connect jumper wire from switch load side to outlet Hot side.
Open following link for instructions with illustration:
http://waterheatertimer.org/How-to-wire-Cooper-277-pilot-light-switch.html#combo

Add a comment for more help.

Take a moment and rate answer for accuracy:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on electrical wiring or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

I just purchased a Cooper Wiring Device 277W-box w/pilot light. The current switch in my home is next to another light switch which operates my hallway light. The other switch (the one I want to install...

Open following link for wiring diagram with written instructions.
Some of your wiring does not sound up to code.
http://waterheatertimer.org/How-to-wire-Cooper-277-pilot-light-switch.htm

1) Two differences between regular switch and cooper 277
-Different color screws: Regular switch has two brass screws, and either wire can connect to either screw. Cooper 277 has dark, brass, silver screws, and hot wire connects to dark screw, and wire to light connects to brass screw.
-Cooper needs neutral wire connected to silver screw, to power the indicator light.

2) Some of the wiring in your box does not sound up to code.
Bare ground wire should not be connected to black and white wires.
Electrician should check this out.
Probably the ground wire is being used as a Neutral. Bare ground wires and white neutral wires both connect to neutral busbar at main breaker box.
0helpful
1answer

I've installed a 60-minute Woods timer 12842 (digital) in my garage but it switches itself off prematurely over and over. I notice when it is on the little green 10min timer light clicks & dims ever so...

Open following link to identify timer for sure, download on-line manual, and read wiring instructions.
ttp://waterheatertimer.org/Woods-timers-and-manuals.html#59000

1) Manual says 1000Watt Tungsten (incandescent) and 1000Watt Ballast (fluorescent)
2) Timer is powered by electric circuit and not internal battery, so cold garage temps will not affect operation
3) Check wiring against instructions shown on link above, except your other timers work fine, which indicates correct wiring.
4) Buy cheap circuit analyzer at home center, and test receptacle on same garage circuit
5) Try moving known-good timer to same location and see if problem persists.
6) I test timers, and some in-wall and plug-in timers arrive defective, and some go bad quickly, most have 1 year limited warranty, some last 5-7 years.

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

Okay, I have the same problem... It is a cooper combination switch. There are two black wires that are coming out of the back . the instructions don't mention them at all. I am installing a new outlet...

Ok you have GFCI combination switch-plug.

Wires coming out of back of device are connected to "Load" wires.
Load are the black and white wires that go to fan, light, motor.

The black and white wires coming from circuit breaker connect to terminals marked "Line"
Look at back of device for markings.
Black wire from breaker goes to brass screw, white wire goes to silver screw.

There is one more set of screws on device. Device usually arrives with tape over these two screws.
This is what those screws are for: If you are working in a junction box, then three cables enter box.
One cable is for Line wires from breaker box.
Second cable goes to Load (light-fan-motor) that is controlled by switch.
Third cable goes forward to another switch or outlet >> and those wires connect to last set of screws on combo device. Black to brass and white to silver.

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you via e-mail while you work on circuit or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

How do you change a 2 wire ballast to a ballast with a black and white wire,2 reds and two blues.I have a 2 tube 18 inch fluorescent lamp with 2 ballasts in it.Each ballast has 2 wires coming out of...

Dear sir

first do not confuse by the colour of ballast wire, now see black and white wire who is coming from the ballast and find out after that you have to remove it from the joint . and other new ballast replace here and it's wire connect here with that point where you has remove wire black and white wire first from here. and try to fix fluorescent light here and after that try to switch on electric supply for testing. i hope after that it will work.

thank you
hope answer the question
please vote!
7helpful
1answer

I need the wiring diagram for a Cooper 277W single pole switch with pilot light. The light is to be on when the switch is on. Thanks!

I have 120Volt cooper 277 pilot light switch here in my office.
Dang instruction sheet shows wiring for all kinds of cooper devices.
EXCEPT pilot light switch.

So I tested with multimeter and came up with following:
Key to any wiring device is color of screws.
Hot from breaker box always goes to dark-colored screws.
Neutral always goes to silver-colored screws.
Brass screws are for Hot wires from breaker or Hot going to Load
Green screw - ground
geno_3245_130.jpg
0helpful
1answer

Installed cooper single pole lighted light swith, switch doesn't light. whats wrong?

People frequently write fixya report that lighted device doesn't light up.
And they report device is wired correctly.
Or they report one device lights up and the other doesn't.
If two devices don't work, I suggest they swap devices to see if same problem happens in other location. No fixya customer has added comment to reveal result of swapping device.

After searching Leviton, Lutron and Cooper websites, there is no conclusive answer.
Manuals show lighted devices, and show ordinary one-for-one replacement wiring ... there is no secret technique for getting device to light, just attach wires like ordinary switch.

Check that ground wire is connected.
Install device in another switch location and see if it works there, which would indicate possible electrical ground fault at first location.
The wrong device was put inside the sales box.
The device is defective.
Not finding what you are looking for?

66 views

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

CJ Rock
CJ Rock

Level 3 Expert

4429 Answers

Are you an Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...