Unit is blowing cool air but not cold air , the unit is 5 years old,
When the unit is running, go outside and put your hand near the condenser fins, this air that comes out should be slightly warmer than the ambient temp. If it is not you will need to take the unit out of the window and out of its outer case and clean the condenser fins from the inside, this is no easy task as it is very hard to reach. You will want to get a small (toothbrushed sized) brass bristled brush with a long handle. Make sure the evaporator coil (in the front) recieves the same attention and wash the mesh filter that goes in front of the evaporator. Re- assemble and enjoy the cold air.
4,808 views
Usually answered in minutes!
TRUCK AC NOT HOUSE
×