SC390 = Toner Density Sensor abormality
Possible causes:
- Poor concentration of developer
- Toner density sensor faulty
Are the prints/copies coming out ok? If the copies are very faint or heavily overtoned then changing the developer may cure the error code. If the copies look OK then you probably need to get the toner density sensor replaced by an engineer.
Hope this helps.
×