NEED TO REPLACE SUCH PART
This is a normal optocoupler. Try to replace it by something like 4N35.
The part CQY80NG however has a footprint of 10 mm wide. The 4N35 has about 7,5 mm width. But this is feasble by bending the legs somewhat outwards.
See also the link to the datasheet. The original can be found at Farnell.