Shutdown 12 blue blinks - Pioneer PDP-5010FD 50 in. Plasma HDTV

1 Answer

Kirkland Crownie

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 4 Answers
  • Posted on May 02, 2014
Kirkland Crownie
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: May 02, 2014
Answers
4
Questions
0
Helped
7864
Points
4

Replace the main assy

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Microsoft lifecam shutdown causes BSOD

hi how are you
i need webcam driver blink f=3.85mm 10xdigitalzoom
0helpful
1answer

What does it mean when the hitachi hd1080 tv will not turn on & a blue light keeps blinking

Depends on model but the set is in shutdown as something is wrong.
0helpful
1answer

All I get is a blue welcome screen on my Mitsu WD-65C9 DLP TV. After several seconds of blue screen, it always just shuts down. I downloaded the Mitsubishi software upgrade, but it did NOT solve...

Hi Mike,

May I know if the LED light at the front panel has a pattern of flashes or flashing continuously in green color.

Please check if you can access the "Self diagnostic screen" by following the steps below.
- To activate, press the front panel "Activity" and "Channel down" buttons at the same time and hold for 5 secs. The Status led will then flash a two digit code. Example, if the error code is "23" the led light flashes 2 times(blink, blink) pause and then flash 3 times(blink, blink, blink). Let me know the error code, it will help to diagnose where the fault came from.
Note : the TV must be in shutdown not switched off, or AC power cord is removed because the code will reset to "12" means no error. Use the front panel buttons not on the remote control. If you can't access the self diagnostic, press and hold the "Activity" button on the front panel for 5 secs before entering the "self diagnostic" code.


Kind Regards,

Mjsazon
1helpful
1answer

Kp-65wv700 7 blinks

hello High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.

shaun
0helpful
1answer

Blue led power light blinks even after shutdown

What operating system are you using? When the power led continues to slowly blink, that means that the laptop is in standby mode and not fully shut down. In Vista, if you hit the power button on the laptop or the power button under the start button, it is configured to go to standby and not shut down. Make sure to hit the arrow all the way to the right and select shutdown from the list of dropdown options.
0helpful
1answer

GREEN BLINKING DOES NT STOP

Shutdown Causes: Cause #1 This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems. To activate this turn the unit on let it shutdown then press the input and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source) 1. Shutdown at power with self diagnosis error 2-2. Check for open fuses F9A04 and F9A05 part # 283P144080 on the +24 and -24 volt lines. If the fuses are open the convergence output circuit would be suspect. 2. Shutdown at power with self diagnosis error 2-1. At power on check for 12-volts DC at connector KH pin 8, if missing check IC9C51 part # 270P990010 and L9C52 part # 441D009020 on the Signal PCB
0helpful
1answer

Tv wont turn on

hello, usually if your panny is blinking it means theres trouble with your power supply but depending on the number of blinks cuased by a fualty or shorted internal board and this will cuase your tv to go into shutdown mode, it depends on your model number and year it was made.
your best bet is to have a qualified service tech give you a estimate for the repair needed. as long as your screen is okay it will be easy for the service tech to locate and fix your trouble

panasonic blinking codes can pin point the troubled internal part, these blinking fualts are cuase by internal boards with malfunctioning circuts info below for 10th gen 2007 2008 plasma model service

12 Blinks SOS:
On the A board, transistor Q2301 monitors the Sound 15V line and the operation of the audio power amplifier IC2301. If the audio output circuit, IC2301, or the 15V lines develops a short to ground, transistor Q2301 goes into conduction and applies a high to pin 118 of the MPU, IC1100, triggering a SOS condition. The power LED blinks 12 times.
12 Blinks SOS: We have also discovered that 12 blinks of the power LED may also be caused by a defective SS board. To determine the source of the shutdown, disconnect the connector D5 and connect the unit to the AC source. If the panel turns on and the LEDs of the SS and SC boards stay on, the problem is on the A board. If the panel does not stay on, the problem is likely to be the SS board.

hope this helps
0helpful
1answer

Blue Screen and then shuts off.

Is the LED blinking a 2 digit code? Let me know mitsubishi will blink a repeating diagnostic code when theset goes into shutdown. Which is what your set is doing. let me know if you can distinquish a blink code from the LED.
0helpful
1answer

WS-55315 with only red bulb

It seems that you donot have the 200+ V line for the GREEN,BLUE. This line is the same as the read line, check connectors located on crt boards make sure they did not come apart. Also you can:This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems. To activate this turn the unit on let it shutdown then press the input and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source) 1. Shutdown at power with self diagnosis error 2-2. Check for open fuses F9A04 and F9A05 part # 283P144080 on the +24 and -24 volt lines. If the fuses are open the convergence output circuit would be suspect. 2. Shutdown at power with self diagnosis error 2-1. At power on check for 12-volts DC at connector KH pin 8, if missing check IC9C51 part # 270P990010 and L9C52 part # 441D009020 on the Signal PCB
0helpful
1answer

Blue screen

This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems. To activate this turn the unit on let it shutdown then press the input and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source) 1. Shutdown at power with self diagnosis error 2-2. Check for open fuses F9A04 and F9A05 part # 283P144080 on the +24 and -24 volt lines. If the fuses are open the convergence output circuit would be suspect. 2. Shutdown at power with self diagnosis error 2-1. At power on check for 12-volts DC at connector KH pin 8, if missing check IC9C51 part # 270P990010 and L9C52 part # 441D009020 on the Signal PCB.
Not finding what you are looking for?

212 views

Ask a Question

Usually answered in minutes!

Top Pioneer Televison & Video Experts

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

matt martin
matt martin

Level 3 Expert

1259 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Pioneer Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...