Amana PTH123B25AJ Heat Pump Air Conditioner Logo

Related Topics:

A
Anonymous Posted on Jan 07, 2014

Amana through the wall unit has fp code

Fp code

5 Related Answers

hvac1960

R Subramaniyam Iyer

  • 2133 Answers
  • Posted on Dec 21, 2010

SOURCE: Unit shows a code fp.

CODE= FP
STATUS = Freeze Protection Engaged. The room temperature measured by the wirelessremote thermostat or indoor ambient thermistor active sensor falls below 40°F.
SUGGESTED ACTION = No Action required. This setting will disengage when theroom temperature rises above 43°F
Is sit helpful?

Ad

Anonymous

  • 1 Answer
  • Posted on Feb 27, 2009

SOURCE: service code FP

I know some manufacturer's use the code FP for Freeze Protection.

Anonymous

  • 26 Answers
  • Posted on Jan 24, 2010

SOURCE: its 15 degrees outside and my amana unit is off.

fp means freeze protection.it comes on by it self so pipes in th house dont freeze.and if it only blows cold air one of the heat protectors is probaly bad

Anonymous

  • 26 Answers
  • Posted on Jan 24, 2010

SOURCE: Unit Won't Cool Or Heat Just Blows Air and Displays FP

fp means freeze protection when gets too cold out unit comes on by itself so pipes dont freeze

Anonymous

  • 4 Answers
  • Posted on May 07, 2010

SOURCE: What does the code F1 & F6 mean for the Amana

These codes signify black (F1) or yellow (F6) thermistor problems. May need replaced.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers
1helpful
1answer

I have an LG hotel ac/heat ptac unit. It is showing a code of FP what does this mean?

I'm pretty sure the FP code means freeze protection engaged. It prevents the outside coil from freezing
1helpful
1answer

Braker trips, and when re-start the unit FP shows

Sorry to read about your problem, I hope this helps you out.

You have a defective compressor tripping the breaker or control card issue. The FP means you had a power failure, hence the breaker trip.

Their is nothing you can do. I do not think you have the equipment to repair or test the unit.

I tried to help you. Please help me and Rate/Vote on my response. We take the time to answer your question. take the time to rate us.Thanks and good luck

4 Thumbs - Very Helpful
3 Thumbs - Helpful
5helpful
1answer

Unit shows a code fp. What does this mean?

CODE= FP
STATUS = Freeze Protection Engaged. The room temperature measured by the wirelessremote thermostat or indoor ambient thermistor active sensor falls below 40°F.
SUGGESTED ACTION = No Action required. This setting will disengage when theroom temperature rises above 43°F
Is sit helpful?
0helpful
1answer

Panasonic error code E01-22 Model FP-D250 photocopier. what does the error code mean? Thanks Nick 0771 8982344/ 01530 519234

E1-22 indicates a problem with the Polygon Motor Sychronization....this is a problem in the laser unit either the Driver pcb is shorted or broken, the Laser unit pcb is defective, the laser unit itself could be defective.
1helpful
2answers

Blowing of cold air every 5 minutes, and it says FP on the screen

FP is the code for frost or freeze protection. The unit will automatically do this periodically to prevent any damage caused by low temperatures although it should not be running as frequently as every five minutes. If the outside temperature is not low then it could either be a problem with the exterior thermistor (not the one you see from inside your room) or the control board could be on its way out.
2helpful
2answers

Its 15 degrees outside and my amana unit is off. every so often it kicks on by itself and runs for about 10 seconds then shuts off again. while it is running the control panel flashes FP, what is it trying...

I was wondering the same thing about our unit until I found the specs online and read that it has freeze protection. When the temp goes below 40 degrees, the fan comes on to prevent damage to the unit.
1helpful
1answer

Service code FP

I know some manufacturer's use the code FP for Freeze Protection.
1helpful
1answer

Unit Won't Cool Or Heat Just Blows Air and Displays FP

fp means freeze protection when gets too cold out unit comes on by itself so pipes dont freeze
Not finding what you are looking for?

2,435 views

Ask a Question

Usually answered in minutes!

Top Amana Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you an Amana Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...