Malfunction detected
Ahhh, you must be the same Macdaniel I emailed for clarification a short while ago.
C2551 relates to the Cyan imaging unit, the machine thinks the toner level inside the Cyan imaging unit is low.
Opening and shutting the main front door is the reset procedure. However if this doesn't work you should try the following
Remove the Cyan imaging unit, give it a bit of a shake and then refit.
Experience tells me that the above only works on occasion and you will probably require a new imaging unit. They are available for around £250.
Please be aware that the fault could also be down to a circuit board being defective, but this is less common.
Regards
Taminol
U can tray tcr toner su play
Or clean out the toner feed assembly with compressed air. It is located under the toner trough in the front. Then it asked me to open and close the bottom front door. Done and done and fixed.