Konica Minolta bizhub 350 All-In-One Laser Printer Logo
Posted on May 18, 2009

Replacing Image Transfer Roller Unit & Paper Dust/Ozone Remover

We have a Konica Minolta Bizhub C350 which is now indicating that it needs to have the image transfer roller unit and paper dust/ozone filter replaced. Where are these located in the machine? Is this something that I can do, or do I need to call in a technician?

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 15 Answers
  • Posted on Jan 15, 2010
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Jan 15, 2010
Answers
15
Questions
0
Helped
9249
Points
25

Hi this unit located in the RIGHT DOOR

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

How do I fix when copies coming out crooked from adf and glass on Konica Minolta Di3510f. All trays doing it. It was recently moved.

check the right door the sponge looking roller and area around it for a problem that section is call registration aligning the paper up before the image goes on it the sponge roller actually trans fer the image on to the paper so the problem is before it check the mylar clear plastic before the the transfer roller section should be on the assembly or below it also check the paper dust remover it clips in on the assy.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

0helpful
1answer

Jumping paper in regaster rooler

Open the right side door and check for proper insertion of Paper dust remover beside transfer roller. Not proper inserted Paper dust remover cause paper to jumping register roller.
0helpful
1answer

Fuser unit

can you explain more the functions of each are as followed fuser melts the toner to the paper so it dosnt rub off ozone filter filters out the ozone so you don't get headaches and turn al the rollers to bubble gum transfer roller pushes the paper onto the transfer belt applying the image to the paper and imagine unit is where thetransfer belt gets the image from
0helpful
1answer

I am having L code errors on our Konica Minolta Biz Hub 363

Sir/Mam,
#10 Transfer roller needs replacing sponge looking roller right side of the of the machine when you open to remove paper jams.

# 9 Developing unit needs replacement that the part that holds the drum and developer/toner. IF YOU YANK THIS UNIT OUT WITHOUT REMOVING THE LITTLE COVER ONE BOLT and DICONNECT THE CONNECTOR. BIG TROUBLE, going to cost a lot to repair.

#8 PAPER DUST REMOVER the device that collect paper dust yes paper does produce DUST. Just before the sponge roller

#6 IS Warning that the developer has not been replace inside the drum cartridge. SEE #9

#4 Drum need to be replaced.

Really have to watch for all of that sir/mam.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

0helpful
1answer
0helpful
1answer

How do I get into menu to reset consumables ?? Like ozone filter, paper dust filter, transfer roller unit

Press "utility/counter" then "details" then stop, 0, 0, stop, 0, 1
This gets you into service mode.
Then press Counter the Life.
Be very careful not to mess with much in the service mode tho.
Good Luck andThank You for using Fixya
1helpful
1answer

Where do I find the Paper Dust Remover/Ozone Filter and the Transfer Roller Unit?

I believe the filter is located on the right or left side. The "Transfer Roller Unit" is the foam roller inside the right door.
0helpful
1answer

I have a Konica Minolta Bizhub C350 which is now indicating that it needs to have the image transfer roller unite and paper dust/ozone filter replaced. Where are these located in the machine and is it...

I would advise having a copier technician replace those items it is not that hard to do but if you dont get the roller seated in the holder properly it can destroy the transfer belt and that could get expensive
0helpful
1answer

Bizhub C450: After replacing the image transfer roller & ozone

In Service Mode -> Counter -> Life -> Select the one you want to reset and press 'C'
4helpful
1answer

Reseting counter after installing new image transfer roller unit

You need to go into tech rep mode to reset.
press: stop 0 0 stop 0 1, then 0 0 0 0 0 0 0 0, press enter, then press counter on the left, select life, then highlight image trans roller and press the C button, repeat for paper dust remover and exit tech rep mode
Not finding what you are looking for?

1,967 views

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...