Ingersol Rand T30 keeps pumping and won't shut off and pressure release valve blows and keep running. I replaced the pressure release switch and it didn't help. Any suggestions?
The wire juction box on your compressor has a pressure switch that may be wound in to tight take the cover off the box there should be a switch with a machine screw with nut and washer and spring back this nut off and see if that helps if you go to far you just crank it back in until the switch hit although it may be the other way around you may have to tighten to lower the pressure some of them are made that way if this does not solve your problem send me a picture of the switch and can solve it from there
Either you've got a bad pressure switch, or possibly the wiring is not hooked up right. I assume it's wired 220 L1 and L2 are your main power supply, T1 and T2 go to the motor(on my compressor not IR though).
1,850 views
Usually answered in minutes!
Don't know where the safety disconnect is at?
Is there any sort of shutoff for servicing or for in case something like this happens? It should be a lockable safety switch with a lever on the outside so that a maint. person can lock it out for personal safety.
Can you tell if the contactor opens when you turn off the safety disconnect?
×