Kenmore Elite HE4 Electric Dryer Logo
J
Jay Duhamel Posted on Nov 24, 2013

GEW9200 electric dryer turns fine but won't heat up. I tested the thermal fuse, thermostat, heating coil and they are fine. What am I missing?

I replaced the control panel about 9 months ago.

1 Answer

Smitty

Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Champion:

An expert who has answered 200 questions.

  • Contributor 240 Answers
  • Posted on Nov 25, 2013
Smitty
Contributor
Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Champion:

An expert who has answered 200 questions.

Joined: Sep 28, 2009
Answers
240
Questions
0
Helped
66211
Points
50

If you have 240 VAC to the dryer, the control likely has a faulty relay for the heater. Provided all the thermal fuses (especially the one on the side of the element can) are good and the voltage supply is good, the control will likely need to be replaced and is available below.


Control


GEW9200 electric dryer turns fine but won't heat u - 00707667.jpg

5 Related Answers

Anonymous

  • 460 Answers
  • Posted on May 13, 2009

SOURCE: my dryer not heat

I need to know the model n serial# to assist you better
Thank you

Ad

Anonymous

  • 1776 Answers
  • Posted on Sep 25, 2009

SOURCE: Kenmore gas dryer no heat

The thermal fuse is easy to test. Just check continuity using a multimeter or ohmmeter. A lack of continuity means a blown thermal fuse.
The coils are difficult to test. You can use a multimeter or ohmmeter and check for continuity, but the problem is that a coil may be sticking open only after heating up, so you can see the difficulty this would present. If a coil is suspected of being faulty, it is best to replace both (all) at the same time. These coils are what permit the gas valves to open and they can cause a no light or a cycling condition. Really sorry for your trouble and I hope this helped. Best wishes.

TheMobilian

Dan Webster

  • 8221 Answers
  • Posted on Oct 04, 2010

SOURCE: Kenmore electric dryer Model 63932:

The motor relay is probably shot.

If you need further help, reach me via phone at https://www.6ya.com/expert/dan_73bbd84fe1d95b61

Anonymous

  • 5911 Answers
  • Posted on Oct 08, 2010

SOURCE: I have a Kenmore Elite

Did you check the igniter? You never mentioned anything about checking, or replacing the igniter. The most common cause of a no heat problem on a GAS dryer is worn or blown igniter. These appliances are equipped with a burner assembly with electronic igniters. The following link explains a little theory about how these igniters work:

http://www.fixya.com/support/r401858-replacing_oven_igniter_gas_range

I know the link is for a gas range, but the burner assembly functions are nearly identical, as well as, the type igniters used.

If you are having ignition problems it is probably a simple matter of a weak or bad igniter. The burner assembly will ignite automatically as long as the gas valve, igniter coils and igniter are all functioning properly. It can take up to 90 seconds for the burner to ignite. As the igniter ages, you may experience longer ignition times.

Replacement parts can be purchased at any of the following websites:
searspartsdirect.com pcappliancerepair.com appliancepartspros.com repairclinic.com All these sites have competitive pricing, so shop and compare. The first three sites listed also have helpful exploded view parts illustrations to assist you with locating and properly identifying any parts you may need.

If you have any questions, please post back and let me know. I hope this information is helpful to you.

Sal De

  • 2699 Answers
  • Posted on Nov 05, 2010

SOURCE: electric dryer won"t heat. Kenmore Heavy Duty 70

are you getting power down to the heater?why did you change all those other parts?you need to unplug the dryer,with a meter read out all the parts you changed out again but first make sure you have 240 volts coming to the machine,you can check it at the cord in the back,touch the white to the red,you should have 110 volts or 120,then go from the white to the black and you should have the same thing,if not the problem is in the house,if it's correct make sure you have power coming down to the heater,you could have a bad timer or a burnt wire,when you check the other parts unplug the dryer and whatever part you check at least one wire has to be removed,do this and you'll find your problem,if you did this first you wouldn't of bought all those parts.let me know what you find

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2helpful
1answer

Dryer wont heat

The only thing left to check is the voltage at the heating coil. IF it is not present then the timer or relay is bad.
0helpful
1answer

Runs with air but won't heat electric mqdel

Hi ticonn1...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,then you do not have to tape the wires together as described above.
But do not trust the ohm meter all the time, because sometimes it will give a false positive that the fuse is ok when in reality it is faulty.
DO THE FOLLOWING TEST:
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
This test of the thermal fuses,thermistor,thermostat, will show if the thermal fuse,thermostat,thermister is really faulty or not.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
DO THE FOLLOWING: Remove the wires and tape them together and try to start the dryer.If the dryer starts then replace the fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on air fluff/no heat, and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up
10helpful
1answer

Our frigidaire gallery dryer won't heat up. It turns fine, and we have tried it on multiple settings.

Hi mommylein...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up
0helpful
1answer

My Kenmore He4 electric dryer is not heating. It is running fine, but does not heat to dry the clothes. What do I need to do?

Hi tomsavaloja...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up
5helpful
1answer

Fisher paykel dryer won't heat / dry clothes.

Hi ducktalk61...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me thumbs up
0helpful
1answer

My Maytag dryer is not heating up. It runs fine. Model PY2300AYW

Hi peaseg13...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me
0helpful
1answer

It sounds about like many of the guests on this site (FixYa). My dryer runs and turns fine, but does not heat on any setting.

Hi joracheff...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me
0helpful
1answer

Replaced heating element,2 relays & still no heat. Checked 220. ok if the door switch makes the dryer run, could it still be the door switch that won't let it heat?

Hi margorothehis..
Yes, it is possible the door switch is faulty not allowing it to heat.
I will send you my generic fix, you have already checked some of these,you might have missed one.
Please rate me
-----------------------------------------------------------------------------------------------------------------------------------------------Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor/thermal fuse one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuse remove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset.
You can test it with an Ohm meter or continuity checker, remove both wires from the thermal fuse and put the test probes to each of the ends of the thermal fuse, if no continuity then replace the thermal fuse.
A vent clogged with lint can cause it to overheat.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace a generic element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
Please take time to rate me
Sep 03, 2011 • Dryers
3helpful
1answer

Electric dryer won,t heat/replaced heating element last year,dryer worksbut won't hea

Hi galepezz...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuseremove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset. A vent clogged with lint can cause it to overheat. You can test it with an Ohm meter or continuity checker, if no continuity, replace it.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
Please take time to rate me
0helpful
1answer

Electric dryer won,t heat/replaced heating element last year,dryer worksbut won't hea

Hi galepezz...

Here are a few things to check:
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor one at a time by removing the two wires and taping them together with electrical tape.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
To test your thermostat/thermistor/thermal fuseremove the wires from the thermostat/thermistor/thermal fuse and check for continuity, if you DO NOT have continuity then replace the thermostat/thermistor/thermal fuse.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.
Check your blower wheel to make sure it is secure to the shaft and not plugged with lint,socks,etc.
If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset. A vent clogged with lint can cause it to overheat. You can test it with an Ohm meter or continuity checker, if no continuity, replace it.
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
Please take time to rate me
Not finding what you are looking for?

94 views

Ask a Question

Usually answered in minutes!

Top Kenmore Dryers Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Kenmore Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...