SOURCE: can I change the 3 phase to a single phase?
Not practical. You would have to change the pump motor to single phase, you'd have to chage the heating element most likely depending on what size is in it now. Also does it require an auxiliary water heater? it's probably 3 phase also. Changing phases is not like changing voltages.
SOURCE: looking for a hobart amx dishwasher wiring diagram
sr. we are using Hobart dish /w but not working this properly .when i start d/w display red light coming but not green light also heater working water coming can you help me
MOTOR:
21?2 H.P., Hobart designed, high torque ball bearing,
ventilated within mixer enclosure. Single-phase is
capacitor-start, induction-run type.
Three-phase is
polyphase squirrel cage, induction-run type.
Single Phase 208V 20.0 Amps
240V 17.0 Amps
Three Phase 208-240V 8.6 Amps
218 views