E032-0001
Description
The NE controller counter malfunctions.
An open circuit is detected for the count pulse signal.
Remedy
Turn off the main power, and check the cable for an open circuit; then, turn the main power back on.
Error code E000019-0000 is a waste toner full error, in order to get rid of this error you need to remove the waste toner bottle located in the left side of the machine
×